INSTALLATION
11
INSTALLATION
Continued
1.Frame in rough opening. Use dimensions shown in Figure 16 for the rough opening.
2.If using blower, install wiring and properly ground the three- prong, 120 volt electrical outlet in fireplace.
3.Before replacing bottom of firebox, install duplex outlet to the right support bracket in the bottom of firebox (see Figure 17).
4.Route wires from electrical box through smallest hole in outer casing using strain relief fitting provided (see Figure 17).
5.Connect wires from the electrical box to duplex outlet. Match wire colors to those indicated on duplex outlet. Be sure to con- nect ground wire.
6.Install shield to end of right support bracket and behind the firebox wrapper with 2 screws provided (see Figure 18).
7.Plug blower cord into duplex outlet. Note: On thermostat model fireplaces, route power cord to the back of the fireplace to clear thermostat valve.
8.Replace bottom of firebox.
9.Install gas piping to fireplace location. This installation includes an approved flexible gas line (if allowed by local codes) after the equipment shutoff valve. The flexible gas line must be the last item installed on the gas piping. See Installing Gas Piping to Fireplace Location, pages 12 and 13.
10.Carefully set fireplace in front of rough opening with back of fireplace inside wall opening.
11.Attach flexible gas line to gas supply. See Connecting Fire- place to Gas Supply, pages 13 and 14.
12.Plug electrical cord into electrical outlet installed in step 2.
13.Carefully insert fireplace into rough opening.
14.Attach fireplace to wall studs using nails or wood screws through holes in nailing flange (see Figure 19).
15.Check all gas connections for leaks. See Checking Gas Con- nections, pages 14 and 15.
16.Install brass trim after final finishing and/or painting of wall (see Figure 7, page 8).
17 3/4"
33"
35 1/2"
Figure 16 - Rough Opening for Installing in Wall
| Cable from |
| Electrical |
| Source |
Blower | Duplex |
| Outlet |
Blower | Strain |
Power | |
Cord | Relief |
| Fitting |
| Support |
| Bracket |
| Screw |
Figure 17 - Connecting Duplex Outlet
Support Bracket
Firebox
Wrapper
Shield
Power Screws
Cord
Figure 18 - Attaching Fireplace to Wall Studs (FPVF33PRA Shown)
Nails or
Wood
Screws
Nailing Flanges
Figure 19 - Attaching Fireplace to Wall Studs (FPVF33PRA Shown)