Desa Tech CGD3930N, CGD3018N, CGD3924N Installing, Continued, Checking Gas Connections

Models: CGD3930N CGD3924N CGD3018N

1 32
Download 32 pages 2.91 Kb
Page 17
Image 17
CHECKING GAS CONNECTIONS

INSTALLING

Continued

CAUTION

Avoid damage to regulator. Hold gas regulator with wrench when connecting it to gas piping and/or fittings.

From

Gas Meter

(5" W.C.** to

10.5" W.C. Pressure)

Tee Joint

Pipe

Nipple

Cap

Sediment

Trap

A.G.A. Design-Certified

Manual Shutoff Valve

With 1/8" NPT Tap*

Approved Flexible Gas Hose (if allowed by local codes)

Gas

Regulator

3" Minimum

Figure 13 - Gas Connection

*Purchase the optional A.G.A. design-certified manual shutoff valve from your dealer. See Accessories, page 29.

**Minimum inlet pressure for purpose of input adjustment.

CHECKING GAS CONNECTIONS

WARNING

Test all gas piping and connections for leaks after installing or servicing. Correct all leaks at once.

WARNING

Never use an open flame to check for a leak. Apply a mixture of liquid soap and water to all joints. Bubbles forming show a leak. Correct all leaks at once.

Pressure Testing gas Supply Piping system

Test Pressures In Excess Of 1/2 PSIG

1.Disconnect heater and its individual manual shutoff valve from gas supply piping system. Pressures in excess of 1/2 psig will damage heater regulator.

2.Cap off open end of gas pipe where manual shutoff valve was connected.

Continued

102986

17

Page 17
Image 17
Desa Tech CGD3930N, CGD3018N, CGD3924N installation manual Installing, Continued, Checking Gas Connections