TROUBLE- SHOOTING
Continued
OBSERVED | POSSIBLE |
|
| |
PROBLEM | CAUSE | REMEDY | ||
|
|
|
|
|
Burner does light | 1. | Burner orifice clogged | 1. | Clean burner (see |
after ODS/pilot is lit |
|
|
| Cleaning and Mainte- |
|
|
|
| nance, page 23) or |
|
|
|
| replace burner orifice |
| 2. | Inlet gas pressure is | 2. | Contact local natural gas |
|
| too low |
| company |
| 3. | Burner orifice diameter | 3. | Replace burner orifice |
|
| is too small |
|
|
|
|
|
|
|
Delayed ignition | 1. | Manifold pressure is | 1. | Contact local natural gas |
burner |
| too low |
| company |
| 2. | Burner orifice clogged | 2. | Clean burner (see |
|
|
|
| Cleaning and Mainte- |
|
|
|
| nance, page 23) or |
|
|
|
| replace burner orifice |
|
|
|
|
|
Burner backfiring | 1. | Burner orifice is | 1. | Clean burner (see |
during combustion |
| clogged or damaged |
| Cleaning and Mainte- |
|
|
|
| nance, page 23) or |
|
|
|
| replace burner orifice |
| 2. | Damaged burner | 2. | Replace damaged burner |
| 3. | Gas regulator defective | 3. | Replace gas regulator |
|
|
|
| |
Slight smoke or | 1. Not enough air | 1. | Check burner for dirt | |
odor during initial |
|
|
| and debris. If found, |
operation |
|
|
| clean burner (see |
|
|
|
| Cleaning and Mainte- |
|
|
|
| nance, page 23) |
| 2. | Gas regulator defective | 2. | Replace gas regulator |
| 3. | Residues from manu- | 3. | Problem will stop after a |
|
| facturing processes |
| few hours of operation |
|
| and logs curing |
|
|
|
|
|
| |
Moisture/condensa- | 1. Not enough combus- | 1. | Refer to Air for Com- | |
tion noticed on |
| tion/ventilation air |
| bustion and Ventilation |
windows |
|
|
| requirements (page 5) |
|
|
|
| |
Heater produces a | 1. Turning control knob | 1. | Turn control knob to LO | |
whistling noise |
| to HI position when |
| position and let warm up |
when burner is lit |
| burner is cold |
| for a minute |
| 2. | Air in gas line | 2. | Operate burner until air |
|
|
|
| is removed from line. |
|
|
|
| Have gas line checked |
|
|
|
| by local natural gas |
|
|
|
| company |
| 3. | Air passageways on | 3. | Observe minimum |
|
| heater blocked |
| installation clearances |
|
|
|
| (see pages |
| 4. | Dirty or partially | 4. | Clean burner (see |
|
| clogged burner orifice |
| Cleaning and Maintenance, |
|
|
|
| page 23) or replace |
|
|
|
| burner orifice |
Continued
102986
25