CONNECTING TO GAS SUPPLY

INSTALLING

Continued

Masonry Screw

Mounting

Bracket

Figure 12 - Attaching Base Assembly to Fireplace Floor

CONNECTING TO GAS SUPPLY

NOTICE

A qualified service person must connect heater to gas supply. Follow all local codes.

CAUTION

WARNING ICON

G 001

Never connect heater directly to the propane supply. This heater requires an external regulator (not supplied). Install the external regulator between the heater and propane supply.

Installation Items Needed

Before installing heater, make sure you have the items listed below.

external regulator (supplied by

• test gauge connection *

 

installer, see page 16)

sediment trap

piping (check local codes)

• tee joint

• sealant (resistant to propane/LP gas)

pipe wrench

• manual shutoff valve *

*An A.G.A. design-certified manual shutoff valve with 1/8" NPT tap is an acceptable alternative to test gauge connection. Purchase the optional A.G.A. design-certified manual shutoff valve from your dealer. See Accessories, page 33.