INSTALLATION
Continued
9.Plug in blower power cord to duplex outlet
(see Figure 10, page 12).
10.Using ON/OFF rocker switch to turn blower on and check for operation. Turn blower off before continuing.
11.Peel off backing paper and stick supplied wiring diagram decal on firebox bottom approximately 12" in from of blower (see
Figure 16).
12.Replace all panels and/or brick bottom panel if previously removed.
Duplex Box/
Handy Box
Strain Relief
Figure 17 -
110/115 |
| ON/OFF |
|
|
|
| ||
| Panel Switch |
|
|
|
| |||
| V.A.C. |
|
|
|
|
| ||
| Black |
|
|
|
|
| ||
| Hot |
|
|
|
|
| ||
|
| Blower | Blower | Blower | ||||
|
|
|
| |||||
Nuetral |
| Motor | Motor | Motor | ||||
Black | No. 1 | No. 2 | No. 3 |
Figure 16 - BK3 Wiring Diagram
NOTICE: A qualified electrician mustconnectelectricalwiringto duplex outlet for
The “Handy Box” with duplex outlet is provided in the firebox located in the lower right base area.
1.Remove screw holding duplex outlet cover to handy box. Remove duplex outlet.
2.Route electrical cable through strain relief and handy box (see Figure 17).
3.Connect electrical cable to duplex outlet.
Match wire colors to those on duplex out- let. Be sure to connect the ground wire.
4.Place duplex outlet back into handy box and secure with screws. Replace outlet cover.
COMBUSTION AIR KIT MODEL AK4 (OPTIONAL)
The outside air kit may be installed on the left side of the fireplace only. The vent can be installed through any outside wall a minimum of three feet below fireplace termination cap. The handle to operate the damper door for the outside air inlet will be located inside the left “screen pocket” of the firebox (see Figure 18). Pull the handle to open or push to close.
CAUTION: Air inlet ducts are not to terminate in attic space.
Screen Pocket
Air Kit
Handle
Figure 18 - Air Kit Handle Location
www.fmiproducts.com | 15 |