CHECKING GAS CONNECTIONS

CONNECTING TO GAS SUPPLY

Continued

CHECKING GAS CONNECTIONS

14

IMPORTANT: Hold pressure regulator with wrench when connecting it to gas piping and/or fittings.

 

 

Pressure

 

 

 

Regulator

3/8" NPT

 

 

 

Pipe Nipple

 

 

 

 

 

Heater

 

 

 

Cabinet

 

Ground Joint Union

 

 

 

Manual

Tee Joint

 

 

 

 

 

Shutoff

Reducer

 

Test

Valve *

 

Bushing to

Gauge

From

 

 

1/8" NPT

Connection *

External

 

 

 

1/8" NPT

 

 

Gas Meter

 

 

 

(4" W.C. to

 

Plug Tap

 

 

 

 

 

 

10.5" W.C.

 

Tee

 

 

Pressure)

3" Minimum

Joint

 

 

 

 

 

 

 

 

Pipe

Sediment Trap

 

 

Nipple

 

 

Cap

Figure 12 - Gas Connection

*An A.G.A. design certified manual shutoff valve with 1/8" NPT tap is an acceptable alternative to test gauge connection. Purchase the optional A.G.A. design certified manual shutoff valve from your dealer. See Accessory, page 28.

PRESSURE TESTING GAS SUPPLY PIPING SYSTEM WARNING

Test all gas piping and connections for leaks after installing or servicing. Correct all leaks at once.

Manual background WARNING

Never use an open flame to check for a leak. Apply a mixture of liquid soap and water to all joints. Bubbles forming show a leak. Correct all leaks at once.

PRESSURE TESTING GAS SUPPLY PIPING SYSTEM

Test Pressures In Excess Of 1/2 PSIG

1.Disconnect heater and its individual manual shutoff valve from gas supply piping system. Pressures in excess of 1/2 psig will damage heater regulator.

2.Cap off open end of gas pipe where manual shutoff valve was connected.

3.Pressurize supply piping system by either using compressed air or opening main gas valve located on or near gas meter.

103574