CLEANING AND MAINTENANCE
TROUBLE-
SHOOTING
Note: All troubleshooting items are listed in order of operation.
WARNING
WARNING ICON | G 001 |
Turn off heater and let cool before cleaning.
CAUTION
WARNING ICON | G 001 |
You must keep control areas, burner, and circulating air passageways of heater clean. Inspect these areas of heater before each use. Have heater inspected yearly by a qualified service person. Heater may need more frequent cleaning due to excessive lint from carpeting, bedding material, etc.
ODS/PILOT AND BURNER ORIFICE
• Use a vacuum cleaner, pressurized air, or small, soft bristled brush to clean.
CABINET
Air Passageways
•Use a vacuum cleaner or pressurized air to clean.
Exterior
•Use a soft cloth dampened with a mild soap and water mixture. Wipe the cabinet to remove dust.
|
| WARNING |
| WARNING ICON | G 001 |
Turn off heater and let cool before servicing. Only a qualified | ||
service person should service and repair heater. | ||
|
|
|
|
|
|
| WARNING ICON | G 001CAUTION |
Never use a wire, needle, or similar object to clean ODS/pilot. This | ||
can damage ODS/pilot unit. |
| |
|
| |
OBSERVED | POSSIBLE | |
PROBLEM | CAUSE | REMEDY |
|
|
|
When ignitor button is pressed, there is no spark at ODS/pilot
1.Ignitor cable pinched or wet
2.Ignitor electrode not connected to ignitor cable
3.Piezo ignitor nut is loose
4.Broken ignitor cable
5.Ignitor electrode broken
6.Bad piezo ignitor
7.Ignitor electrode posi- tioned wrong
1.Free ignitor cable if pinched by any metal or tubing. Keep ignitor cable dry
2.Reconnect ignitor cable
3.Tighten nut holding piezo ignitor to heater cabinet. Nut is located inside heater cabinet at top
4.Replace ignitor cable
5.Replace ignitor
6.Replace piezo ignitor
7.Replace ignitor
21
103574