Desa Tech CGP10 installation manual TROUBLE- Shooting, Low

Models: CGP10

1 28
Download 28 pages 3.26 Kb
Page 22
Image 22

TROUBLE- SHOOTING

Continued

OBSERVED

POSSIBLE

 

 

PROBLEM

CAUSE

REMEDY

 

 

 

 

 

Burner does not light

1.

Burner orifice is

1.

Clean burner orifice (see

after ODS/pilot is lit

 

clogged

 

Cleaning and Mainte-

 

 

 

 

nance, page 20) or replace

 

 

 

 

burner orifice

 

2.

Burner orifice diameter

2.

Replace burner orifice

 

 

is too small

 

 

 

3.

Inlet gas pressure is

3.

Contact local propane gas

 

 

too low

 

company

Delayed ignition of 1.

Manifold pressure is

burner

too low

2.

Burner orifice is

 

clogged

1.Contact local propane gas company

2.Clean burner orifice (see Cleaning and Mainte- nance, page 20) or replace burner orifice

Burner backfiring dur- 1.

Burner orifice is

ing combustion

clogged or damaged

2.

Burner damaged

3.

Gas regulator defective

1.Clean burner orifice (see Cleaning and Mainte- nance, page 20) or replace burner orifice

2.Replace burner

3.Replace gas regulator

22

Yellow

flame during

1.

Not enough air

1.

Check burner for dirt and

burner combustion

 

 

 

debris. If

found, clean

 

 

 

 

 

burner (see Cleaning and

 

 

 

 

 

Maintenance, page 20)

 

 

2.

Gas regulator defective

2.

Replace gas regulator

 

 

 

 

 

 

Slight smoke or odor

1.

Residues from manu-

1.

Problem will stop after a

during

initial opera-

 

facturing processes

 

few hours of operation

tion

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Heater

produces a

1.

Turning control knob

1.

Turn

control

knob

to

whistling noise when

 

to HIGH position

 

LOW

position

and

let

burner is lit

 

when burner is cold

 

warm up for a minute

 

 

 

2.

Air in gas line

2.

Operate burner until air is

 

 

 

 

 

removed from line. Have

 

 

 

 

 

gas checked by local pro-

 

 

 

 

 

pane gas company

 

 

 

3.

Air passageways on

3.

Observe minimum instal-

 

 

 

heater blocked

 

lation

clearances (see

 

 

 

 

 

Figure 4, page 10)

 

 

 

4.

Dirty or partially

4.

Clean burner (see Clean-

 

 

 

clogged burner orifice

 

ing and Maintenance,

 

 

 

 

 

page

20)

or

replace

 

 

 

 

 

burner orifice

 

 

099403

Page 22
Image 22
Desa Tech CGP10 installation manual TROUBLE- Shooting, Low