TROUBLE-

WARNING

SHOOTING

If you smell gas

Continued

• Shut off gas supply.

• Do not try to light any appliance.

 

Do not touch any electrical switch; do not use any phone in your building.

Immediately call your gas supplier from a neighbor’s phone. Follow the gas supplier’s instructions.

If you cannot reach your gas supplier, call the fire department.

IMPORTANT: Operating heater where impurities in air exist may create odors. Cleaning supplies, paint, paint remover, cigarette smoke, cements and glues, new carpet or textiles, etc., create fumes. These fumes may mix with combustion air and create odors.

OBSERVED

POSSIBLE

 

 

 

 

PROBLEM

CAUSE

 

REMEDY

 

 

 

 

 

 

 

 

 

Heater produces a

1.

Metal expanding while

1.

This is common with

 

clicking/ticking noise

 

heating or contracting

 

most heaters. If noise is

 

just after burner is lit or

 

while cooling

 

excessive, contact quali-

 

shut off

 

 

 

 

fied service person

 

 

 

 

 

 

 

 

 

Heater produces un-

1.

Heater burning vapors

1.

Ventilate room. Stop us-

 

wanted odors

 

from paint, hair spray,

 

ing odor-causing prod-

 

 

 

 

 

glues, etc. (See IMPOR-

 

ucts while heater is run-

 

 

 

 

 

TANT statement above)

 

ning

 

 

 

 

2.

Low fuel supply

2.

Refill supply tank

 

 

 

 

3.

Gas leak. See Warn-

3.

Locate and correct all

 

 

 

 

 

ing statement at

 

leaks (see Checking Gas

 

 

 

 

 

top of page

 

Connections, page 14)

 

 

 

 

 

 

 

 

 

Heater shuts off in use

1.

Not enough fresh air is

1.

Open window and/or

 

(ODS operates)

 

available

 

 

door for ventilation

 

 

 

 

2.

Low line pressure

2.

Contact local propane

 

 

 

 

 

 

 

 

gas company

 

 

 

 

3.

ODS/pilot

is partially

3.

Clean ODS/pilot (see

 

 

 

 

 

clogged

 

 

Cleaning and Mainte-

 

 

 

 

 

 

 

 

nance, page 20)

 

 

 

 

 

 

 

 

Gas odor even when

1.

Gas leak. See Warn-

1.

Locate and correct all

 

control knob is in OFF

 

ing statement at

 

 

 

leaks (see Checking Gas

 

position

 

top of page

 

 

 

 

Connections, page 14)

 

 

 

 

2.

Control valve defective

 

 

 

 

 

2.

Replace control valve

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Gas odor during com-

1.

Foreign matter between

1.

Take apart gas tubing

 

bustion

 

control

valve and

 

 

 

and remove foreign mat-

 

 

 

 

 

burner

 

 

 

 

 

 

 

 

 

ter

 

 

 

 

2.

Gas leak. See Warn-

 

 

 

 

 

2.

Locate and correct all

 

 

 

 

 

 

 

 

ing statement at

leaks (see Checking Gas

top of page

Connections, page 14)

 

 

 

 

 

23

099403

Page 23
Image 23
Desa Tech CGP10 If you smell gas, Shut off gas supply, Do not try to light any appliance, Ing statement at, Top