Brocade Communications Systems 6910 manual IronWare traps, General traps

Models: 6910

1 80
Download 80 pages 30.19 Kb
Page 72
Image 72

IronWare traps

IronWare traps

This section presents the IronWare traps supported on devices running IronWare software.

NOTE

The Traps in the IronWare MIBs include the following lines in their description:

--#TYPE "Brocade Trap: Power Supply Failure"

--#SUMMARY "Power supply fails, error status %d." --#ARGUMENTS { 0 }

--#SEVERITY MINOR

--#STATE OPERATIONAL

These lines are used by the HP OpenView network management system.

General traps

The table below lists the general traps generated by devices. Refer to the previous sections in this chapter to determine if traps for a feature need to be enabled.

Trap Name and Number

Varbind

Severity

Description

 

 

 

 

snTrapUserLogin

snAgGblTrapMessage

Informational

The SNMP trap that is generated

brcdIp.0.75

 

 

when a user logs in to a device.

 

 

 

Sample Trap Message:

 

 

 

Security: telnet login

 

 

 

from src IP 10.37.21.63 to

 

 

 

USER EXEC mode.

 

 

 

 

snTrapUserLogout

snAgGblTrapMessage

Informational

The SNMP trap that is generated

brcdIp.0.76

 

 

when a user logs out of a device.

 

 

 

Sample Trap Message:

 

 

 

Security: telnet logout

 

 

 

from src IP 10.37.21.63

 

 

 

from USER EXEC mode.

 

 

 

 

snTrapClientLoginReject

snAgGblTrapMessage

Informational

The SNMP trap that is generated

brcdIp.0.110

 

 

when a login attempt by a telnet or

 

 

 

SSH client fails.

 

 

 

Format:

 

 

 

Security: {snmp sshtelnet web}

 

 

 

access [by user <name>] from src [IP

 

 

 

<ipv4> IPv6 <ipv6>] rejected, <n>

 

 

 

attempts

60

Brocade 6910 Ethernet Access Switch MIB Reference

 

53-1002582-01

Page 72
Image 72
Brocade Communications Systems 6910 manual IronWare traps, General traps