52 Brocade 6910 Ethernet Access Switch MIB Reference
53-1002582-01

Global ARP statistics

Global ARP statistics

The following are the MIB objects display statistics for ARP.

Support for optical monitoring

The following objects are for support in Ethernet optical monitoring. They are equivalent to the

show interfaces transceiver CLI command.

Name, Identifier, and Syntax Access Description
snArpStatsTotalReceived
brcdIp.1.1 .3.22.1.1
Syntax: Counter32
Read only The total number of ARP packets received from the interfaces,
including those received in error.
snArpStatsRequestReceived
brcdIp.1.1 .3.22.1.2
Syntax: Counter32
Read only The total number of input ARP request packets received from
the interfaces.
snArpStatsRequestSent
brcdIp.1.1 .3.22.1.3
Syntax: Counter32
Read only The total number of output ARP request packets sent from the
interfaces.
snArpStatsRepliesSent
brcdIp.1.1 .3.22.1.4
Syntax: Counter32
Read only The total number of output ARP reply packets sent from the
interfaces.
Name, Identifier, and Syntax Access Description
snIfOpticalMonitoringInfoTable
brcdIp.1.1 .3.3.6
N/A This table lists the instrumented parameters of all optical
interfaces.
snIfOpticalMonitoringInfoEntry
brcdIp.1.1 .3.3.6.1
Syntax: Unsigned32
N/A The snIfOpticalMonitoringInfoEntry specifies the optical
parameters of the specified interface. Only the ifIndices of
optical interfaces whose parameters need to b e monitored
will be used to index this table.
snIfOpticalMonitoringTemperature
brcdIp.1.1 .3.3.6.1.1
Syntax: DisplayString
Read only This object holds the value of the transmitter laser diode
temperature for the interface. This object indicates the
health of the transmitter.
The format is [-]xxx.yyyy C(elsius), followed by whether the
measured value is normal, high/low alarm or high/low
warning.
snIfOpticalMonitoringTxPower
brcdIp.1.1 .3.3.6.1. 2
Syntax: DisplayString
Read only This object holds the value of the transmitter optical signal
power for the interface, measured in dBm, followed by
whether this is a normal value, or high/low warning or alarm.
snIfOpticalMonitoringRxPower
brcdIp.1.1 .3.3.6.1. 3
Syntax: DisplayString
Read only This object holds the value of the receiver optical signal
power for the interface, measured in dBm, followed by
whether this is a normal value, or high/low warning or alarm.
snIfOpticalMonitoringTxBiasCurrent
brcdIp.1.1 .3.3.6.1. 4
Syntax: DisplayString
Read only Tx Bias Current. It is measured in mA, and is followed by
whether this is a normal value, or high/low warning or alarm.