INSTALLATION
Continued
NOTICE: Surface temperatures of adjacent walls and mantels become hot during operation. Walls and mantels above the firebox may become hot to the touch. If installed properly, these temperatures meet the requirement of the national product standard. Follow all minimum clearances shown in this manual.
| 10" |
| Mantel Shelf |
| Underside | ||
|
|
|
|
| |||
| 8" |
|
|
|
| ||
|
|
|
|
| of Mantel | ||
| 6" |
|
|
|
| Shelf | |
| 2 1/2" |
|
|
|
|
| |
|
|
|
|
| All minimum | ||
|
|
|
|
| distances | ||
|
|
|
|
| are in inches | ||
Minimum | (A) |
|
|
|
| Log Set | |
Noncombustible |
|
|
|
| |||
|
|
|
| 24"/30" | |||
Material | 12" | 18" | 20" | 22" | 24" | ||
Models | |||||||
| |||||||
| 8" | 8" | 14" | 17" | 20" | 18" Model | |
|
|
|
|
| Top of Fireplace | ||
|
|
|
|
| Opening | ||
| Minimum |
| Distances to |
|
| ||
| Noncombustible | Underside of |
|
| |||
| Material Height | Mantel |
|
|
|
Figure 6 - Minimum Mantel Clearances
Without Using Hood
|
| 12" |
|
| Mantel Shelf |
|
|
|
|
| ||
|
|
|
|
|
|
|
|
| Underside | |||
|
| 10" |
|
|
|
|
|
|
| of Mantel | ||
|
| 8" |
|
|
|
|
|
|
| Shelf | ||
|
|
|
|
|
|
|
|
| ||||
|
|
|
|
|
|
|
|
|
|
|
| |
|
| 6" |
|
|
|
|
| All minimum | ||||
|
|
|
|
|
|
| ||||||
|
| 2 1/2" |
|
|
|
|
| |||||
|
|
|
|
|
|
|
| distances are | ||||
Minimum |
|
|
|
|
|
|
| in inches | ||||
|
|
|
|
|
|
|
|
|
|
|
| |
Noncombustible |
|
|
|
|
|
|
|
|
| Log Set | ||
Material |
| 8" |
| 12" | 15" | 18" | 20" |
|
| All | ||
|
|
|
|
|
| Models | ||||||
|
|
| Min. |
|
|
|
|
|
|
| ||
|
|
|
|
|
|
|
| Top of | ||||
|
|
|
|
|
|
|
|
|
| |||
|
|
|
|
|
|
|
|
|
| |||
|
|
|
|
|
|
|
|
|
| Fireplace | ||
|
| Hood | Distances to |
|
|
| Opening |
(GA6050,, | Underside of | |
GA6052)and | Mantel | |
GA6053) | ||
|
NOTICE:Ifyourinstallationdoes not meet the minimum clearances shown, you must do one of the following:
•operate logs only with flue damper open
•raise mantel to an acceptable height
•remove mantel
Floor Clearances
A.If installing appliance on the floor level, you must maintain the minimum distance of 14" to combustibles (see Figure 8).
B.If combustible materials are less than 14" to the fireplace, you must install appliance at least 5" above the combustible flooring
(see Figure 9).
Combustible
14" Material
Min.
Noncombustible
Material
Figure 8 - Minimum Fireplace Clearances
if Installed at Floor Level
Hearth
Combustible Material
5"
Min.
Figure 9 - Minimum Fireplace Clearances
Above Combustible Flooring
Figure 7 - Minimum Mantel Clearances
When Using Hood
www.desatech.com | 11 |