INSTALLATION
Continued
2.Open main gas valve located on or near gas meter for natural gas or open pro- pane/LP supply tank valve.
3.Make sure control knob of heater is in the OFF position.
4.Check all joints from equipment shutoff valve to thermostat gas valve (Ther-
5.Correct all leaks at once.
6.Light heater (see Operation, page 19
7.Turn off heater (see To Turn Off Gas to Appliance, page 20
Propane/LP | Equipment |
Supply Tank | Shutoff Valve |
Thermostat Gas Valve or Control Valve Location
Figure 17 - Checking Gas Joints
(Propane/LP Gas Models)
Equipment
Shutoff Valve
Gas Meter
Thermostat Gas Valve or
Control Valve Location
Figure 18 - Checking Gas Joints (Natural
Gas Models)
INSTALLING LOGS
CAUTION: After installation and periodically thereafter, check to ensure that no flame comes in contact with any log. With the heater set to HI, check toseeifflamescontactanylog.If so, reposition logs according to the log installation instructions in this manual. Flames contacting logs will create soot.
WARNING:Failuretoposition thepartsinaccordancewiththese diagrams or failure to use only parts specifically approved with this heater may result in property damage or personal injury.
Dual Burner Biltmore Split Oak Models CCL3018PTA/NTA, CCL3924PTA/NTA Each log is marked with a number. These numbers will help you identify the log when installing. It is very important to install these logs exactly as instructed. Do not modify logs. Only use logs supplied with heater.
1.Place front log (#1) on grate fingers. Make sure front log rests firmly between grate fingers and grate base (see Figure 19).
2.Place base of middle log (#2) in
Front
Log (#1)
Grate
Fingers
Grate
Base
Figure 19 - Installing Front Log #1
(CCL3924PTA/NTA Shown)
16 | www.desatech.com |