www.fmiproducts.com 116986-01H12
CONNECTING TO GAS SUPPLY
WARNING: This appliance
requires a 1/2" NPT (National
Pipe Thread) inlet connection
to the shutoff valve.
WARNING: A qualied service
person must connect heater to gas
supply. Follow all local codes.
CAUTION: Never connect
propane/LP replace directly
to the propane/LP supply. This
heater requires an external regu-
lator (not supplied). Install the
external regulator between the
heater and propane/LP supply.
WARNING: Never connect
natural gas replace to private
(non-utility) gas wells. This
gas is commonly known as
wellhead gas.
INsTallaTIoN
Continued
Fitting
Flexible Gas Hose
(if allowed by local
codes)
Figure 10 - Attaching Flexible Gas Hose
to Regulator
Installation Items Needed
Before installing heater, make sure you have
the items listed below.
• external regulator (for propane/LP units
only, supplied by installer)
• piping (check local codes)
• sealant (resistant to propane/LP gas)
• equipment shutoff valve *
• test gauge connection *
• sediment trap
• tee joint
• pipe wrench
• approved exible gas line with gas connec-
tor (if allowed by local codes)
* A equipment shutoff valve with 1/8" NPT
tap is an acceptable alternative to test gauge
connection. Purchase the optional equipment
shutoff valve from your dealer. See Acces-
sories, page 25.
For propane/LP units, the installer must
supply an external regulator. The external
regulator will reduce incoming gas pressure.
You must reduce incoming gas pressure to
between 11" and 14" of water. If you do not re-
duce incoming gas pressure, heater regulator
damage could occur. Install external regulator
with the vent pointing down as shown in Figure
11. Pointing the vent down protects it from
freezing rain or sleet.
CAUTION: Use only new,
black iron or steel pipe. Inter-
nally-tinned copper tubing may
be used in certain areas. Check
your local codes. Use pipe of
1/2" diameter or greater to allow
proper gas volume to heater. If
pipe is too small, undue loss of
volume will occur.
Figure 11 - External Regulator With Vent
Pointing Down
Propane/LP
Supply Tank External
Regulator
with Vent
Pointing
Down
Installation Items Needed
• control cover kit (provided with heater)
• approved exible gas hose (if allowed by
local codes)
• sealant (resistant to propane/LP gas, not
provided)
1. Apply pipe joint sealant lightly to male
threads of gas fitting (not provided).
Connect approved exible gas hose to
inlet side of gas control (see Figure 10).
IMPORTANT: Hold gas tting with wrench
when connecting exible gas hose.
2. Position heater assembly in replace.
3. Connect to gas supply. See Connecting
to Gas Supply.