IMPORTANT SAFETY INSTRUCTIONS
• SAVE THESE INSTRUCTIONS •
IMPROPER OPERATION OR MAINTENANCE OF THIS PRODUCT COULD RESULT IN SERIOUS INJURY AND PROPERTY DAMAGE. READ AND UNDERSTAND ALL WARNINGS AND OPERATING INSTRUCTIONS BEFORE USING THIS EQUIPMENT.
|
| HAZARD |
|
| WHAT CAN HAPPEN |
|
|
| HOW TO PREVENT IT |
|
| ||||||||||||||||||
|
|
|
| Air Tank |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
|
|
|
| • | THE | FOLLOWING | CONDITIONS |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||||
| RISK OF BURSTING |
| COULD lead to a weakening of the tank, |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||||||||
|
| and RESULT IN A VIOLE NT TANK |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |||||||
|
|
|
|
| EXPLOSION: |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||
|
|
|
|
| 1. FAILURE TO PROPERLY DRAIN | • DRAIN TANK DAILY OR AFTER EACH | |||||||||||||||||||||||
|
|
|
|
| condensed WATER FROM THE |
| USE. If tank develops a leak, replace it | ||||||||||||||||||||||
|
|
|
|
| TANK, causing rust and thinning of |
| immediately with a new tank or new | ||||||||||||||||||||||
|
|
|
|
|
| ||||||||||||||||||||||||
|
|
|
|
| the tank steel. |
|
|
|
| compressor outfit. |
|
|
|
|
|
|
|
| |||||||||||
|
|
|
|
| 2. MODIFICATIONS or attempted | • NEVER drill into, weld, or MAKE ANY | |||||||||||||||||||||||
|
|
|
|
|
| MODIFICATIONS TO THE TANK or its | |||||||||||||||||||||||
|
|
|
|
| repairs TO THE TANK. |
|
|
|
|
|
|
|
|
|
|
|
|
| |||||||||||
|
|
|
|
|
| attachments. Never attempt to repair a | |||||||||||||||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
| damaged or leaking tank. Replace with | ||||||||||||||||
|
|
|
|
| 3. Unauthorized MODIFICATIONS |
| a new tank. |
|
|
|
|
|
|
|
|
|
|
|
|
| |||||||||
|
|
|
|
| • The tank is designed to withstand |
|
| ||||||||||||||||||||||
|
|
|
|
| TO THE PRESSURE SWITCH, |
| specific operating pressures. NEVER | ||||||||||||||||||||||
|
|
|
|
| SAFETY VALVE, OR any OTHER |
| MAKE ADJUSTMENTS OR PARTS | ||||||||||||||||||||||
|
|
|
|
| COMPONENTS WHICH |
| SUBSTITUTIONS TO alter the |
|
| ||||||||||||||||||||
|
|
|
|
| CONTROL tank PRESSURE. |
| FACTORY SET operating |
|
|
|
|
|
| ||||||||||||||||
|
|
|
| Attachments and Accessories |
| PRESSURES. |
|
|
|
|
|
|
|
|
|
|
|
|
| ||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||||||||
|
|
|
| • EXCEEDING THE PRESSURE RATING | • | Follow the equipment manufacturers | |||||||||||||||||||||||
|
|
|
|
| OF AIR TOOLS, spray guns, air operated |
| recommendation and never exceed the | ||||||||||||||||||||||
|
|
|
|
| accessories, | tires | AND other |
| maximum allowable pressure rating of | ||||||||||||||||||||
|
|
|
|
| INFLATABLES CAN CAUSE THEM TO |
| attachments. |
| NEVER | USE |
| THE |
| ||||||||||||||||
|
|
|
|
| EXPLODE or fly apart, and could result in |
| COMPRESSOR TO INFLATE SMALL | ||||||||||||||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||||||||||
|
|
|
|
| serious injury. |
|
|
|
|
|
| LOW | |||||||||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
| AS CHILDREN’S TOYS, FOOTBALLS, | ||||||||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
| BASKETBALLS, ETC. |
|
|
|
|
|
|
|
| ||||||||
|
|
|
|
|
|
|
|
| |||||||||||||||||||||
|
|
|
| • Your AIR COMPRESSOR is powered by | • | Any ELECTRICAL | WIRING | OR | |||||||||||||||||||||
|
|
|
|
| electricity. Like any other electrically |
| REPAIRS required to this product | ||||||||||||||||||||||
| RISK OF ELECTRIC |
| powered device, IF it is NOT USED |
| SHOU LD BE PERFORMED BY | ||||||||||||||||||||||||
|
| PROPERLY it MAY CAUSE |
| QUALIFIED SERVICE PERSONNEL | |||||||||||||||||||||||||
|
| SHOCK |
|
|
|
|
|
|
| OR a LICENSED ELECTRICIAN, in | |||||||||||||||||||
ELECTRICAL SHOCK. |
|
|
|
| |||||||||||||||||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
| accordance with national and local | ||||||||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
| |||||||||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
| electrical codes. |
|
|
|
|
|
|
|
| ||||||||
|
|
|
| • | ELECTRICAL GROUNDING: FAILURE | • | MAKE |
| CERTAIN |
|
| that | the | ||||||||||||||||
|
|
|
|
| TO PROVIDE ADEQUATE GROUND- |
| ELECTRICAL CIRCUIT to which the | ||||||||||||||||||||||
|
|
|
|
| ING TO THIS PRODUCT COULD |
| compressor is connected PROVIDES | ||||||||||||||||||||||
|
|
|
|
|
| ||||||||||||||||||||||||
|
|
|
|
| RESULT IN SERIOUS INJURY OR |
| PROPER ELECTRICAL GROUNDING, | ||||||||||||||||||||||
|
|
|
|
| DEATH FROM ELECTROCUTI ON. |
| CORRECT |
| VOLTAGE, | AND | |||||||||||||||||||
|
|
|
|
| SEE GROUNDING INSTRUCTIONS IF |
|
|
|
|
|
|
|
| ||||||||||||||||
|
|
|
|
|
| ADEQUATE FUSE PROTECTION. |
|
| |||||||||||||||||||||
|
|
|
|
| APPLICABLE. |
|
|
|
|
| • Never operate the compressor outdoors | ||||||||||||||||||
|
|
|
|
|
|
|
|
|
|
|
| ||||||||||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
| when it is raining. |
|
|
|
|
|
|
|
| ||||||||
|
|
|
|
|
|
|
|
| |||||||||||||||||||||
|
|
|
| • It is | normal | for | ELECTRICAL | • Always OPERATE the COMPRESSOR | |||||||||||||||||||||
|
|
|
|
| CONTAC TS within the motor and |
| IN a well ventilated AREA FREE OF | ||||||||||||||||||||||
|
|
|
|
|
|
|
|
|
|
| |||||||||||||||||||
| RISK OF EXPLOSION OR |
| pressure switch to SPARK WHENEVER |
| GASOLINE OR SOLVENT VAPORS. | ||||||||||||||||||||||||
|
| THE | COMPRESSOR STARTS OR |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||||||||
|
| FIRE |
| • | If spraying | flammable |
| materials, | |||||||||||||||||||||
|
|
| STOPS. |
|
|
|
|
|
| ||||||||||||||||||||
|
|
|
|
|
|
|
|
|
|
| LOCATE COMPRESSOR at least 20 | ||||||||||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
| |||||||||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
| FEET AWAY FROM SPRAY AREA. | ||||||||||||||||
|
|
|
|
|
|
|
|
|
|
|
| • STORE FLAMMABLE MATERIALS in a | |||||||||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
| secure | location | AWAY FROM | ||||||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
| COMPRESSOR. |
|
|
|
|
|
|
|
| ||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
4 — ENG