8.Apply sealant to the check valve threads. Reinstall the check valve (turn clockwise).
9.Replace the pressure release tube. Tighten nuts.
10.Replace the outlet tube and tighten nuts.
11.Perform the
To Replace Regulator
1.Release all air pressure from air tank. See "To Drain Tank" in the Maintenance section.
2.Unplug compressor.
3.Remove the outlet pressure gauge and quick connect (if equipped) from the regulator.
4.Remove the regulator.
5.Apply pipe sealant tape to the nipple.
Outlet
Pressure
Gauge
Regulator Quick Connect
Nipple
6.Assemble the regulator and orient as shown.
NOTE: Arrow indicates flow of air. Make sure it is pointing in the direction of air flow.
Regulator
Regulator
Arrow
7.Reapply pipe sealant to outlet pressure gauge and quick connect.
8.Reassemble outlet pressure gauge and quick connect. Orient outlet pressure gauge to read correctly. Tighten quick connect with wrench.
17- ENG | D26195 |