6.After 15 minutes, close the drain valve (clockwise). The air receiver will fill to "cut-out" pressure and the motor will stop.

The compressor is now ready for use.

Before Each Start-Up:

1.Place On/Auto/Off lever to "OFF".

2.Pull regulator knob out, turn counter-clockwise until it stops. Push knob in to lock in place.

3.Attach hose and accessories. NOTE: The hose or accessory will require a quick connect plug if the air outlet is equipped with a quick connect.

Too much air pressure causes a hazardous risk of bursting. Check the manufacturer’s maximum pressure

rating for air tools and accessories. The regulator outlet pressure must never exceed the maximum pressure rating.

How to Start:

1.Turn the On/Auto/Off lever to "AUTO" and allow tank pressure to build. Motor will stop when tank pressure reaches "cut-out" pressure.

2.Pull the regulator knob out and turn clockwise to increase pressure. When the desired pressure is reached push knob in to lock in place. The compressor is ready for use.

NOTE: Always operate the air compressor in well-ventilated areas free of gasoline or other combustible vapors. If the compressor is being used to operate a sprayer DO NOT place near the spray area.

MAINTENANCE

Customer Responsibilities

 

Before

Daily or

 

 

 

each

after

Frequently

Yearly

 

each

 

use

 

 

 

use

 

 

 

 

 

 

Check Safety Valve

 

 

 

Drain Tank

 

 

 

Air Filter

 

 

1

 

 

 

 

 

 

Air compressor pump intake

 

 

 

and exhaust valves

 

 

 

 

 

 

 

 

 

 

 

 

1- more frequent in dusty or humid conditions

 

 

 

 

 

 

 

Unit cycles automatically when power is on. When performing maintenance, you may be exposed to voltage

sources, compressed air, or moving parts. Personal injuries can occur. Before performing any maintenance or repair, disconnect power source from the compressor and bleed off all air pressure.