E N G L I S H
-Physical trauma due to inappropriate lifting and carrying of heavy equipment.
Package contents
The package contains:
1Pavement breaker
1Instruction manual
1Exploded drawing
•Check for damage to the tool, parts or accessories which may have occurred during transport.
•Take the time to thoroughly read and understand this manual prior to operation.
Description (fig. A1 & A2)
D25980 pavement breaker has been designed for professional heavy duty demolition, chipping and chasing applications in concrete, brick, stone and other masonry materials.
Fig. A1
1On/off switch
2Side handle
3Tool retainer
4Tool holder
Optional accessories (fig. A2)
Various types of 28 mm hex. chisels are available as an option.
Consult your dealer for further information on the appropriate accessories.
5Pointed chisel
6Cold chisel
7Scaling tool
8Spade chisel
9Asphalt cutter
10Driver ground rod
11Shank tamper
12Plate tamper
Soft start feature
The soft start feature allows the impact rate to build up more slowly, thus preventing the chisel or point from "bouncing" around on the masonry when starting up.
Fully
The dampers in the handles (2) absorb the vibrations transmitted to the user. This improves user comfort during the operation.
Active vibration control
The active vibration control neutralises rebound vibration from the hammer mechanism. Lowering hand and arm vibration, it allows more comfortable use for longer periods of time and extends the life of the unit.
Electrical safety
The electric motor has been designed for a limited voltage range. Always check that the power supply falls within the voltage range on the rating plate.
Your DEWALT tool is double insulated in accordance with EN 60745; therefore no earth wire is required.
Using an extension cable
If an extension cable is required, use an approved extension cable suitable for the power input of this tool (see technical data). The minimum conductor size is 1.5 mm2.
When using a cable reel, always unwind the cable completely.
Also refer to the table below.
Conductor size (mm2) | Cable rating (amperes)) |
|
| ||||||
0.75 |
|
|
| 6 |
|
|
|
|
|
1.00 |
|
|
| 10 |
|
|
|
|
|
1.50 |
|
|
| 15 |
|
|
|
|
|
2.50 |
|
|
| 20 |
|
|
|
|
|
4.00 |
|
|
| 25 |
|
|
|
|
|
|
|
|
| Cable length (m)) |
|
|
| ||
|
|
|
| 7.5 | 15 | 25 | 30 | 45 | 60 |
|
|
|
|
| |||||
oltage | Amperes | Cable rating (amperes |
|
| |||||
115 | 0 | - | 2.0 | 6 | 6 | 6 | 6 | 6 | 10 |
| 2.1 | - | 3.4 | 6 | 6 | 6 | 6 | 15 | 15 |
| 3.5 | - | 5.0 | 6 | 6 | 10 | 15 | 20 | 20 |
|
|
|
|
|
|
|
|
|
|
| 5.1 | - | 7.0 | 10 | 10 | 15 | 20 | 20 | 25 |
| 7.1 | - 12.0 | 15 | 15 | 20 | 25 | 25 | - | |
|
|
|
|
|
|
|
|
| |
| 12.1 | - 20.0 | 20 | 20 | 25 | - | - | - | |
230 | 0 | - | 2.0 | 6 | 6 | 6 | 6 | 6 | 6 |
|
|
|
|
|
|
|
|
|
|
| 2.1 | - | 3.4 | 6 | 6 | 6 | 6 | 6 | 6 |
| 3.5 | - | 5.0 | 6 | 6 | 6 | 6 | 10 | 15 |
|
|
|
|
|
|
|
|
|
|
| 5.1 | - | 7.0 | 10 | 10 | 10 | 10 | 15 | 15 |
| 7.1 | - 12.0 | 15 | 15 | 15 | 15 | 20 | 20 | |
| 12.1 | - 20.0 | 20 | 20 | 20 | 20 | 25 | - |
8