Maintenance
Figure 3 |
|
| |
Back |
| Log | |
Ledge |
| ||
| Ember | ||
|
| ||
|
| bed | |
Rear | Side Section | Front | |
Tab | Edge | ||
|
Figure 4 |
LED Wire |
Harness |
4.Set logset in front of firebox.
5.Disconnect the logset LED wire harness from unit
(Figure 4).
6.Examine the bulbs to determine which bulbs require replacement.
7.Unscrew bulbs counter clockwise.
8.Insert new bulbs.
9.
10.Replace the log by inserting the rear tab of the logset under the back ledge of the fireplace and push down on the front edge of the logset until it snaps into place (Figure 3).
11.Replace log grate using two screws previously removed.
Purifire™ Filter
The Purifire™ filter supplied in your fireplace is reusable and washable. The filter should be cleaned or replaced on average once a year, or if overheat indicator lamp is activated. To clean the filter gently tap filter on a hard surface to dislodge any loose dirt or debris, and then clean with water. Do not use soap or cleaning products, as they may damage the filter. The filter size is 20” X 10” X
1” rated at MERV 10. If using an after market filter follow the manufacturers recommended replacement instructions.
To replace filter:
1.Remove the 2 mounting screws from the air filter bracket.
2.Slide forward to remove the air filter bracket assembly