Dimplex BF8000ST owner manual New Wall Construction, Existing Fireplace

Models: BF8000ST

1 16
Download 16 pages 47.15 Kb
Page 9
Image 9
New Wall

New Wall

Construction

1.Select a suitable location that is not susceptible to moisture and is away from drapes, furniture and high traffic.

2.Place the fireplace in the desired location to see how it will look in the room.

3.Mark the desired location on the floor.

Figure 5

23 ⅛”

(587 mm)

26 ¾”

(679 mm)

9”

(229 mm)

4.Use studs to frame an opening of 26 ¾ inch (679 mm) wide x 23 ⅛ inch (587 mm) high x 9 inch (229 mm) deep.

Option #1: The power cord can be run from behind the trim and along the wall to an outlet near the fireplace.

Option #2: A new outlet can be installed inside the framing construction.

Plug the unit into a 15 Amp, 120 Volt outlet. If the cord does not reach, you may use an extension cord rated for a minimum of 1875 Watts.

Existing Fireplace

1.Seal all drafts and vents with a non-fibrous insulation material to prevent any chimney debris from falling onto the fireplace. Do not install into an existing fireplace that is prone to dampness.

2.Cap the top of the chimney flue to prevent rain from entering.

3.Plan your electric power supply.

4.The power cord can run along the front of the hearth to an outlet near the fireplace.

Existing Fireplace CAUTION: Clearance for air circulation beneath the fireplace insert is provided by two spacers. Do not install the fireplace insert

9

Page 9
Image 9
Dimplex BF8000ST owner manual New Wall Construction, Existing Fireplace