Testing
1. Set the light level 5to maximum (clockwise), and the time on | to minimum |
2.Move in and out of detection pattern checking the PIR detector switches load on and then off. Once the detection area has been set satisfactorily, adjust the time (blue knob) to the desired level. For your convenience optimum settings have been indicated.
3.If the unit does not operate, refer to the check list and fault finding list.
Check List
1.Check the supply to the detector
2.If the unit is being tested during daylight , ensure that the photocell has been adjusted in accordance with point 1 in the ‘Testing’ section.
3.Check detector is connected to the heater correctly
Fault Finding List
Problem | Solution | |
|
|
|
The unit will not switch on | • | Check power is supplied to the unit |
| • | Check the plug in connection from the detector head is inserted in to the wall box correctly |
| • | Check to see that the lamps are fitted correctly to the heater(s) |
Unit is detecting at too long a range | • | Check mounting height and adjust angle of the unit downwards to reduce range (note the unit is |
|
| designed to switch at a maximum of 15 metres with 170Ib (77kg) person walking at 90º to the |
|
| unit. Alternatively fit an appropriate mask. |
| IMPORTANT: at 10ºC this unit may detect in excess of 20 metres. | |
|
|
|
Unit switches on for no apparent | • | Check the unit is not sited near any vents or heating flues |
reason | • | |
| NOTE: to reduce sensitivity, blank off areas C1, C2, C3, C4 of the lens mask | |
|
|
|
Unit will not switch off | • | Are you standing by the detection zone? Whilst you are moving in and out of the detection area |
|
| the unit will continue to detect. The heater on time is from the last moment detection was made. |
Technical Specification
Switching capability – Up to 3kW Operating Power – 3kW
Detection Range – 15 metres maximum Detection Angle - 180º
Heater on time – Adjustable to 10 seconds, 60 seconds, 3.5 minutes, 6 minutes, 9 minutes, 12 minutes, 13.5 minutes, 16 minutes, 21 minutes (approximately)
IMPORTANT: When unit is first connected to the mains the light will switch on – even in daylight. Allow unit to reset before testing
After Sales Care
Your product is guaranteed for one year from the date of purchase.
Within this period, we undertake to repair or exchange this product free of charge (subject to availability) provided it has been installed and operated in accordance with these instructions.
Your rights under this guarantee are additional to your statutory rights, which in turn are not affected by this guarantee.
Should you require after sales service you should contact the supplier through whom you purchased the product or contact our customer service help desk on 0845 600 5111. It would assist us if you can quote the model number, series, date of purchase, and nature of the fault at the time of your call. The customer service help desk will also be able to advise you should you need to purchase any spares.
Please do not return a faulty product to us in the first instance as this may result in loss or damage and delay in providing you with a satisfactory service.
Please retain your receipt as proof of purchase
Glen Dimplex UK Ltd | UK customer helpline | |
Millbrook House | Customer helpline | Tel. 0845 600 5111 |
Grange Drive | ||
Hedge End |
| Fax. 01489 773053 |
Southampton |
| |
SO30 2DF | Republic of Ireland | Tel. 01 842 4833 |
|
[C] Glen Dimplex UK Ltd.
All rights reserved. Material contained in this publication may not be reproduced in whole or part, without the prior permission in writing from Glen Dimplex UK Limited.