Dimplex DXUF20T, DXUF30T dimensions Models Specification, Electrical connection, Using the Heater

Models: DXUF30T DXUF20T

1 2
Download 2 pages 47.86 Kb
Page 1
Image 1

Fan Heaters

 

 

 

Installation and Operating Instructions

 

 

 

08/35113/0 Issue 0

Model(s) : DXUF20T & DXUF30T

 

(IP20)

 

 

Dimensions

H

W

D

(see Fig. 3)

(millimetres)

 

236

242

175

(see Fig. 2)

Model(s)

Specification

 

 

 

 

DXUF20T

2.0kW Thermostat & Switch

 

 

 

 

DXUF30T

3.0kW Thermostat & Switch

 

 

 

 

Fig. 1

IMPORTANT : THESE INSTRUCTIONS SHOULD BE READ CAREFULLYAND RETAINED FOR FUTURE REFERENCE

IMPORTANT SAFETY ADVICE

READ THESE INSTRUCTIONS BEFORE USE.

DO NOT use the heater on deep pile carpets or the long hair type of rugs, or less than 750mm (30") away from any overhanging surface. Keep combustible materials such as drapes and other furnishings clear from the front, sides and rear of the heater. Do not use heater to dry your laundry.

DO NOT use the heater in the immediate surroundings of a bath, a shower or a swimming pool.

DO NOT place the heater directly below a fixed socket outlet.

The socket-outlet must be accessible at all times to enable the mains plug to be disconnected as quickly as possible.

DO NOT COVER or obstruct the air inlet and outlet openings in any way.

The heater must be on a flat stable surface when in use.

DO NOT operate the heater with the mains lead overhanging the front outlet grille.

NEVER leave the heater unattended when it is used by or near the aged, infirm person’s or children.

The heater carries the Warning symbol indicating that it must not be covered.

The instruction leaflet belongs to the appliance and must be kept in a safe place. If changing owners, the leaflet must be surrendered to the new owner.

IMPORTANT – If the mains lead of this appliance is damaged, it must be replaced by the manufacturer or its service agent or a similarly qualified person in order to avoid a hazard.

WARNING: In order to avoid a hazard due to inadvertent resetting of the thermal cut-out, this appliance must not be supplied through an external switching device, such as a timer, or connected to a circuit that is regularly switched on and off by the utility.

Electrical connection

This heater must be used on an A.C.~ supply only and the voltage marked on the heater must correspond to the supply voltage. This heater is fitted with a plug incorporating a 13 amp fuse. When replacing the fuse, a 13 amp fuse approved by ASTA to BS 1362 must be used.

If the plug is not suitable for the socket outlets in your home, the plug must be cut off and an appropriate one fitted. A plug cut off from a mains lead will give a shock hazard if inserted into a 13 amp socket elsewhere in the house. To avoid this, it should be disposed of immediately.

NOTE: The fuse cover of a non-rewirable plug must be refitted when changing the fuse. Should the cover become lost, the plug must not be used until the correct replacement fuse cover is obtained from your supplier or by contacting our customer helpline.

IMPORTANT : The wires in this mains lead are coloured in accordance with the following code :

BLUE :NEUTRAL

BROWN :LIVE

As the colours of the wires in the mains lead may not correspond with the coloured markings in your plug, proceed as follows :

Connect the BROWN wire to the terminal marked ‘L’ or coloured RED. Connect the BLUE wire to the terminal marked ‘N’ or coloured BLACK. Note : L’ or ‘N’ must not be connected to the EARTH terminal marked

E’ or or coloured GREEN or GREEN AND YELLOW. If in doubt, consult your electrician.

Using the Heater

Heat Control - see Fig. 2

-

OFF

-

Cool Blow*

-

Half heat

-

Full heat

Fig. 2

Thermostat Control - see Fig. 3

The heat output is controlled by the

*thermostat, according to the room

 

temperature.

 

Turn the thermostat knob fully clockwise

 

to maximum setting initially. When the

Fig. 3

room is warm enough, reduce the setting

slowly until the heater just clicks off.

 

The heater will now cycle on and off to maintain your selected room temperature. An audible click may be heard when the thermostat operates - this is normal.

Note : If the heater does not come on when the thermostat is at a low setting, this is normally because the room is warmer than the thermostat setting and is not a fault.

*When the heat control is set to ‘ ‘ for cool blow, set the thermostat control to maximum.

Position ‘*‘ will turn the heater on and off to maintain a temperature of approximately 5°C.