Dimplex manual Heater, Troubleshooting Guide, EF3003, SF3003, DF3003, Problem, Cause, Solution

Models: EF3003

1 4
Download 4 pages 24.32 Kb
Page 3
Image 3
HEATER

EF3003, SF3003, DF3003

TROUBLESHOOTING GUIDE

HEATER

 

Problem

 

 

Cause

 

 

Solution

 

 

Service Manual

 

 

 

 

 

 

 

 

Reference

 

 

 

 

 

 

 

 

 

 

 

 

 

Heater is not

 

 

Defective heater on/off switch

 

Replace heater on/off switch

 

Page 17

 

 

 

 

 

 

 

 

 

 

 

 

 

turning off

 

 

Improper operation

 

See User’s Guide

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Loose wiring

 

Trace wiring in unit

 

Page 9

 

 

 

 

 

 

 

 

 

 

 

 

Heater is not

 

 

Defective heater on/off switch

 

Replace heater on/off switch

 

Page 17

 

 

 

 

 

 

 

 

 

 

 

 

 

turning on

 

 

 

 

 

 

 

 

 

 

 

 

 

Defective heater assembly

 

 

Replace heater assembly

 

 

Page 18

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Improper operation

 

See User’s Guide

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Loose wiring

 

Trace wiring in unit

 

Page 9

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Heater emits an

 

 

 

 

 

Normal operation is when

 

 

 

 

 

 

 

 

 

 

the heater emits an odour for

 

 

 

 

 

odour

 

 

 

 

 

a brief period after the

 

 

 

 

 

 

 

 

Normal operation

 

 

heater is initially turned on.

 

 

 

 

 

 

 

 

 

 

 

The heater is burning off any

 

 

 

 

 

 

 

 

 

 

 

dust accumulated during

 

 

 

 

 

 

 

 

 

 

 

manufacturing or operation.

 

 

 

 

 

 

 

 

Defective heater assembly

 

 

Replace heater assembly

 

 

Page 18

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Loose wiring

 

Trace wiring in unit

 

Page 9

 

 

 

 

 

 

 

 

 

 

 

 

 

Heater fan turns on

 

 

Improper operation

 

See User’s Guide

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

but heater lacks

 

 

Loose wiring

 

Trace wiring in unit

 

Page 5

 

 

heat

 

 

 

 

 

 

 

 

 

 

 

 

 

Defective heater assembly

 

 

Replace heater assembly

 

 

Page 18

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Normal operation

 

 

Small glowing sections of

 

 

 

 

 

 

 

 

 

 

the element are considered

 

 

 

 

 

Heating element is

 

 

 

 

 

normal.

 

 

 

 

 

 

 

 

 

 

If larger glowing sections are

 

 

 

 

 

glowing red

 

 

Defective heater assembly

 

 

causing the heater to trip the

 

 

Page 18

 

 

 

 

 

 

 

thermal cut out, unplug unit,

 

 

 

 

 

 

 

 

 

 

discontinue use and replace

 

 

 

 

 

 

 

 

 

 

 

heater assembly

 

 

 

 

Page 3
Image 3
Dimplex manual Heater, Troubleshooting Guide, EF3003, SF3003, DF3003, Problem, Cause, Solution, Reference