Air Warmer: Model No. HAW1000N

08/50511/0

Issue 0

Dimensions (millimetres)

 

WattsElectrical SupplyWeight (kg)

 

HAW1000N1000230-240V ~1PN

14

115

 

 

 

 

207

470

Fig. 1

THESE INSTRUCTIONS SHOULD BE READ CAREFULLYAND RETAINED FOR FUTURE REFERENCE

Important Safety Advice

Do not locate above or below a fixed socket outlet.

The heater including the supporting legs can get very hot; therefore do not mount directly on any combustible material. Suitable fire resistant material is required between the heater and any combustible base or support.

Warning: Before obtaining access to the terminals all supply circuits must be disconnected.

The heater should be installed to allow a reasonable air flow around the heater.

A prominent notice should be provided where the heater is sited ‘Keep Clear and Unobstructed’.

Avoid exposure to water.

The heaters are not suitable for general domestic use.

The heater is suitable for a drying room provided that the heater has suitable ventilation.

A mains lead which can operate at + 110°C must be used.

An all-pole isolating switch with a minimum separation of 3mm in each pole must be fitted adjacent to the heater to facilitate local isolation.

General

This carton contains:

1 HAW1000N heater

1 Foldable guard

Electrical connection

WARNING – THIS APPLIANCE MUST BE EARTHED.

Verify that the electrical supply cable is sufficient for the rated loading. Check that the incoming supply conforms to the rated supply.

The heater power circuit must be protected by a suitably rated over current device.

The incoming cables must be connected to the factory fitted heater terminals provided. Do not alter any factory fitted wiring.

The Terminal Cover Casting can be removed to access the terminals, by removing the 2 screws fixing the cover - see Fig. 2.

WARNING: Ensure the power cable path does not come into contact with the heater element.

The heater is supplied with an earth stud, located inside the terminal box, which must be connected to earth.

After connection check the continuity of earth connections.

Air Warmer: Model No. HAW1000NWattsElectrical SupplyWeight (kg)HAW1000N1000230-240V ~1PN207Fig. 1Important Safety Advice x

Fig. 2

Installation

The installation should be carried out by a suitably qualified electrician/ engineer in accordance with applicable standards.

Remove all items from the packaging. The heater should be fixed using the fixing points provided - see Fig. 3. Ensure the heater is securely fastened.

179

449

Fig. 3

Remove the terminal cover and connect the mains cable, while making note of the path the connecting cable should take through the guard.

Reattach the terminal cover to the heater and fasten the cable gland.

Mount the guard over the heater. Ensure the guard is mounted centrally relative to the heater as shown in Fig. 4.

The heater should not be connected until the instruction leaflet has been read fully.