1.1 Important Information

CAUTION! Do not open the unit unless all electrical circuits have been disconnected from the power supply.

CAUTION! During transport, the heat pump must not be tilted more than 45° (in either direction).

CAUTION! Heat pump and transport pallet are only connected by the packaging film.

CAUTION! The air intake and discharge openings must neither be constricted nor obstructed.

CAUTION! Clockwise phase sequence (in the case of multiphase units) must be observed: Damage to the compressor may be incurred if it is operated in the wrong sense of rotation.

CAUTION! Do not use any cleaning agents containing sand, soda, acid or chloride as these may damage the surface.

CAUTION! To prevent consequential damage it is imperative that the water circuits be neutralized after cleaning using appropriate agents.

CAUTION! The unit is not suitable for operation with a frequency converter.

CAUTION! Work on the refrigeration circuit may be performed by qualified persons only.

READ IMMEDIATELY

1.2 Legal Provisions and Guidelines

This heat pump was designed and built in compliance with all relevant EU directives, DIN and VDE regulations (see CE Declaration of Conformity).

The electrical connection of the heat pump must be performed according to and conforming with all re- levant VDE, EN and IEC standards. Beyond that, all technical connection requirements of the local electrical utility company have to be adhered to.

On connecting the heating system, all relevant regulations have to be heeded.

1.3Energy-Efficient Use of the Heat Pump

By purchasing this heat pump you contribute to the protection of the environment. A prerequisite for energy-efficient operation is the proper design of the heat source system and the heat utilization system.

One of the most important factors of heat pump efficiency is keeping the temperature difference between the heating water and the heat source as small as possible. It is therefore strongly recommended that the design of both the heat source system and the heat distribution system be carried out with great care. A 1 Kelvin (1°C) higher temperature difference corresponds to an increase in power consumption of approx. 2.5%. When designing the heating system care must be taken that special applications such as domestic water heating are taken into consideration and dimensioned for low temperature operation. Heat pumps are optimally suited for underfloor heating (surface/radiant heating) applications due to the low supply temperatures (30 °C to 40 °C).

During operation it is essential that the heat exchangers are not contaminated as this would increase the temperature difference resulting in a lower coefficient of performance.

3

Page 3
Image 3
Dimplex LA 16TR, LA 8MR, LA 6MR, LA 12TR, LA 10MR Read Immediately, Important Information, Legal Provisions and Guidelines

FAQ

What are the important cautions for handling the heat pump?

The manual includes important cautions such as not opening the unit unless all electrical circuits have been disconnected, and not using cleaning agents containing sand, soda, acid or chloride.

What regulations and standards should be adhered to for electrical connection?

The manual details compliance with EU directives, DIN, VDE regulations, and technical connection requirements of the local electrical utility company.

How can I ensure energy-efficient operation of the heat pump?

The manual provides guidelines for proper design of the heat source system and the heat utilization system to contribute to energy-efficient operation.