FUNCTIONAL DESCRIPTION
8FUNCTIONALDESCRIPTION
8.1 Heat Pump Remote Control Unit
The heat pump can be switched on and off by means of the remote control positioned inside the building. Switching off in this case means switching to a "standby" function, i.e. as long as the heat pump is supplied with mains power, the frost protection function of the heat pump remains active. If the water temperature is too low, first the heating circulating pump, and if this is not enough, also the compressor must be put in operation. The remote control allows you to set the heating or cooling operating mode (the switchover delay from the heating to the cooling mode, or
1 | 2 | 3 |
4
1)Switch On/Standby
2)LED (green) is illuminated regardless of the switch position (indicates operational readi- ness of heat pump)
3)Switch "Heating" (left side depressed) Switch "Cooling" (right side depressed)
4)Dial for selecting heating water setpoint temperature
8.2 Control Board
6 5 4 3 2 1
12
11
7 8 9 10
1) | on | = compressor is operating |
2) | on | = fan is operating |
3) | off | = reversing valve set to "Heating" |
| on | = reversing valve set to "Cooling" or |
|
| "Defrost" |
4) | on | = heating circulating pump is operating |
5) | off | = output backup heater off |
6) | on | = call for frost protection, HP is heating |
| off | = call for frost protection off |
7) | on | = low pressure pressostat okay |
8) | off | = defrost process in progress or |
|
| "Heating mode" |
| on | = defrost process is terminated or |
|
| "Cooling mode" |
9)not used
10)not used
11)flashing during operation
12)flashing in the event of a malfunction
8.3 Heating Function
Set switch (1) to position On (I) to put heat pump into operation. The heating mode can be preselected by placing switch (3) to the Heating () position. The desired return temperature can be set using selector dial (4), the relevant call for heat is controlled by the potentiometer and lies within a range of min. 10 °C and max. 55 °C. If the preset temperature is reached, the heat pump switches off. Once the return temperature drops below the preset temperature by 4 Kelvin, the heat pump switches back on. In the event that the preset return temperature cannot be reached, the output for the