Dimplex SI 24TE SI 37TE manual Equipment Data, Performance data

Models: SI 24TE SI 37TE

1 21
Download 21 pages 2.59 Kb
Page 8
Image 8

12

12 Equipment Data

1Type and order code

2Design

2.1Degree of protection according to EN 60 529

2.2Installation location

3 Performance data

3.1Operating temperature limits:

Heating water flow

°C

 

 

Brine (heat source)

°C

 

 

Antifreeze

Minimum brine concentration (-13 °C freezing temperature)

SI 24TE

IP 21

Indoors

up to 60 -5 to +25 Monoethylene glycol 25%

SI 37TE

IP 21

Indoors

up to 60 -5 to +25 Monoethylene glycol 25%

English

3.2Temperature spread of heating water (flow/return flow) at B0 / W35K

3.3

Heat output / COP

at B-5 / W55 1

kW / ---

 

 

 

kW / ---

 

 

at B0 / W45 1

kW / ---

 

 

 

kW / ---

 

 

at B0 / W50 1

kW / ---

 

 

 

kW / ---

 

 

at B0 / W35 1

kW / ---

 

 

 

kW / ---

3.4

Sound power level

 

dB(A)

3.5

Sound pressure level at a distance of 1 m

dB(A)

3.6Heating water flow with an internal pressure differential of m³/h / Pa

3.7Brine throughput with an internal pressure differential (heat source) of m³/h / Pa

2

3

2

3

2

3

2

3

9.4

19.7/ 2.3 9.3 / 2.1

22.7/ 2.9

10.8/ 2.7

24.0/ 4.3

12.5/ 4.4

2.2/ 3100

5.6/ 13000

5.0

22.3/ 3.1

11.3/ 3.1

23.7/ 4.1

12.7/ 4.3

4.0/ 9800

5.6/ 13000

9.8

28.9/ 2.4

12.1/ 2.2

34.3/ 3.1

13.1/ 2.4

37.2/ 4.6

17.0/ 4.2

3.2/ 1650

8.5/ 10000

5.0

33.0/ 3.3

13.4/ 2.8

35.4/ 4.3

18.3/ 4.5

6.0/ 5100

8.5/ 10000

3.8

Refrigerant; total filling weight

type / kg

4

Dimensions, connections and weight

 

 

 

 

4.1

Device dimensions without connections 4

H x W x L mm

4.2

Device connections to heating system

Inch

 

 

 

4.3

Device connections to heat source

Inch

4.4

Weight of the transportable unit(s) incl. packing

kg

 

 

 

5

Electrical connection

 

5.1

Nominal voltage; fuse protection

V / A

5.2

Nominal power consumption 1 B0 W35

kW

5.3

Starting current with soft starter

A

5.4

Nominal current B0 W35 / cos ϕ 2

A / ---

6Complies with the European safety regulations

7Additional model features

7.1Water in device protected against freezing 6

7.2Performance levels

7.3Controller internal/external

R404A / 3.7

1660 x 1000 x 775

G 1 1/4'' internal/external G 1 1/2'' internal/external 282

400 / 20

5.615.81

20

10.12 / 0.8

10.48 / 0.8

 

 

5

Yes

2

Internal

R404A / 6.8

1660 x 1000 x 775

G 1 1/4'' internal/external

G 2'' internal/external

371

400 / 20

7.968.17

26

14.40 / 0.8

14.92 / 0.8

 

 

5

Yes

2

Internal

1.This data indicates the size and capacity of the system. For an analysis of the economic and energy efficiency of the system, both the bivalence point and the regulation should also be taken into consideration. The specified values, e.g. B10 / W55, have the following meaning: Heat source temperature 10 °C and heating water flow temperature 55 °C.

2.Operation with 2 compressor

3.Operation with 1 compressors

4.Note that additional space is required for pipe connections, operation and maintenance.

5.See CE declaration of conformity

6.The heat circulating pump and the heat pump controller must always be ready for operation.