MAINTENANCE

4.Carefully lift out the precleaner from the fan housing. Clean the fan housing so debris does not fall into the carburetor.

5.Install a new precleaner and the new or cleaned air filter element into the fan housing.

IMPORTANT INFORMATION

Operating the engine with loose or damaged air cleaner components could allow unfiltered air into the engine causing premature wear and failure.

6.Align the tabs on the cover with the slots in the housing and replace air filter cover.

8009-408

Remove precleaner

8009-407

Align the tabs

7. Pull the handle outwards. Secure the handle in the air filter cover and press inwards to close.

8009-410

Close the cover