HYDROSTAT DRIVE BELT

CARE AND MAINTENANCE

HYDROSTAT DRIVE BELT

REPLACEMENT PROCEDURE:

To install hydrostat pump drive belt:

1.Rotate the spring loaded take-up idler towards the left hand hydro pump.

2.Install belt per diagram.

3.Install double u-joint and tighten flange bolts (tighten to 14 ft. lbs.).

4.Install radiator and mounting hardware.

5.Attach radiator hoses and refill cooling system.