CARE AND MAINTENANCE

HYDROSTAT DRIVE BELT

REPLACEMENT PROCEDURE:

To install hydrostat pump drive belt:

1.Rotate the spring loaded take-up idler towards the left hand hydro pump.

2.Install belt per diagram.

3.Install double u-joint and tighten flange bolts (tighten to 14 ft. lbs.).

4.Install radiator and mounting hardware.

5.Attach radiator hoses and refill cooling system.

35

Page 35
Image 35
Dixon 8000D manual Hydrostat Drive Belt Replacement Procedure