Dixon 8000D manual Hydrostatic Pumps, HYDROSTAT DRIVE BELT REPLACEMENT PROCEDURE continued

Models: 8000D

1 44
Download 44 pages 26.26 Kb
Page 34
Image 34

CARE AND MAINTENANCE

HYDROSTATIC PUMPS:

Before each use, check to be sure that the cooling fins of the hydrostatic pumps are clean. Excessive accumulation of oil, dirt, or trash may cause the pumps to overheat. NEVER WASH ACROSS TOP OF RESERVOIR WITH WATER OR STEAM. Fill reservoir as required per the maintenance schedule listed in this book

HYDROSTAT DRIVE BELT

REPLACEMENT PROCEDURE (continued):

To remove hydrostat pump drive belt:

(The hydrostat pump drive is equipped with a spring loaded belt take-up)

1.Raise seat.

2.Drain radiator.

3.Remove radiator mounting hardware and hoses.

4.Remove radiator.

5.Remove double u-joint flange bolts and remove double u-joint.

6.Rotate the spring loaded take-up idler toward the left hand hydro pump to provide belt slack for removal.

7.Remove belt.

34

Page 34
Image 34
Dixon 8000D manual Hydrostatic Pumps, HYDROSTAT DRIVE BELT REPLACEMENT PROCEDURE continued, Care And Maintenance