Dixon ZTR 4518 Operation Instructions, Testing Of Safety Interlock Systems, Engine Should Stop

Models: 13782-0503 ZTR 4518 ZTR 4515 ZTR 4516

1 52
Download 52 pages 39.82 Kb
Page 22
Image 22
ENGINE SHOULD STOP!

OPERATION INSTRUCTIONS

NOTE: If Any Safety Check FAILS, Do Not TESTING OF SAFETY INTERLOCK SYSTEMS:

BLADE DRIVE SWITCH TEST:

a)Put parking brake in ON position.

b)Swing out control levers.

c)Engage blade drive switch.

d)Turn ignition switch to START.

Engine should not turn over or attempt to start.

SEAT SWITCH TEST:

a)In a SAFE AREA away from bystanders, start the engine.

b)Leave levers swung out and parking brake ON.

c)Engage blade drive.

d)Raise slightly off seat.

ENGINE SHOULD STOP!

NOTE: If Any Safety Check FAILS, Do Not

Operate The Mower until the system has been checked and repaired by an Authorized Dixon Dealer.