Dixon ZTR 7025, 13091-0500 Lubrication, Checking & Replenishing Oil In Hydrostatic Transmission

Models: 13091-0500 ZTR 7025

1 40
Download 40 pages 42.51 Kb
Page 26
Image 26
LUBRICATION:

CARE AND MAINTENANCE

LUBRICATION:

A.Engine: Follow engine manufacturer's recommendation.

B.Deck spindles: Lubriacte with 3 "shots" only, every 100 hours.

C.Hydrostatic transmission and filter (follow instructions listed below).

Dirt or water in oil can ruin the hydrostatic transmissions.

CHECKING & REPLENISHING OIL IN HYDROSTATIC TRANSMISSION

Check the oil level in hydrostatic transmission oil reservoir after every 25 hours of usage. Clean the oil reservoir cap and the area around it prior to removal. Check the oil level on the dipstick. The proper oil level should register between the marked hole on the dipstick and the end of the dipstick. Replenish as needed with 20W-50 Motor Oil. DO NOT OVERFILL. When checking the oil level, be very careful to keep the reservoir clean.

Change the oil in the reservoir and hydrostat transmission oil filter after the first 100 hours of use. Then every 500 hours after that. Remove the filter and be sure all oil has drained from the reservoir. Replace with new filter and 20W-50 Mobil Super II.

Oil Reservoir Cap

Dipstick

Fuel Cap

Please dispose of used oil at proper collection centers - protect your environment