PROGRAMMING INSTRUCTIONS |
|
Description
The
What’s needed
Additional equipment needed to program the
386 or better laptop or PC
WindowsTM 95 or 3.1 with a communication software package such as HyperterminalTM or TerminalTM DMP Model 396 programming cable
10BaseT Ethernet cable
Configuration for use with a DMP 462N or 862N
The following configuration is designed for applications where the
1912XR/862N orXR200/462N
Configure the communication software package on your laptop or PC for 9600 baud, 8 bits, no parity 1 stop bit and no flow control. Connect the DMP Model 396 programming cable to the COM port on your laptop or PC that you configured in your communication software. Connect the other end of the Model 396 programming cable to the
DO NOT CONNECT the
Ethernet Address: | Internet Address: 10.17.39.1 | ||
Flash Rom Version | 2.0 (May 12, 1998) |
|
|
Flash Version: | 3.5/1 (970707) |
|
|
Current Diagnostics report: |
|
| |
NVR Config: | Normal | Ram Size: | 256 KB |
CPU Speed: | 10 MHz | Gate Array: | Rev 2 |
Flash Version: | 3.5/1 (970707) | Ethernet: None |
|
Errors: | Network |
|
|
No network was detected. Press a key within 10 seconds to access bootmode commands>
Press the Return key to access the Boot> prompt.
Enter the following commands at the Boot> prompt:
1.CHANGE BOOTP DISABLED
2.CHANGE DHCP DISABLED
2841 E. Industrial Drive Springfield, MO
Downloaded from: http://www.guardianalarms.net