DMP Electronics LT-0424 manual Change Rarp Disabled, Init, Ether-Com Programming

Models: LT-0424

1 4
Download 4 pages 58.43 Kb
Page 2
Image 2
3.CHANGE RARP DISABLED

3.CHANGE RARP DISABLED

Connect the ETHER-COM to an Ethernet network after entering the command in line number 3. It should be connected to the actual network at the location where the ETHER-COM will be permanently installed.

4.INIT 451

The ETHER-COM initialization will begin 5 seconds after pressing the Return key. If the ETHER-COM has been properly attached to a network and no other self-diagnostic errors are encountered, the ETHER-COM will restart. The following messages should then be displayed:

DMP, Inc. ETHER-COM Initialization

 

 

Ethernet Address:

00-80-a3-0f-4a-d4

Internet Address: (Undefined)

Flash Rom Version

2.0 (May 12, 1998)

 

 

Flash Version:

3.5/1 (970707)

 

 

Current Diagnostics report:

 

 

NVR Config:

Normal

Ram Size:

256 KB

CPU Speed:

10 MHz

Gate Array:

Rev 2

Flash Version:

3.5/1 (970707)

Ethernet: UTP

 

Errors:

None

 

 

Skipping DHCP.

 

 

 

Skipping BOOTP.

 

 

 

Skipping RARP.

 

 

 

Checking 2 sections from flash:

 

 

From address 0x20004 to 0x20018,

281414 Bytes) -> not copied.

From address 0x64b5e to 0x210000,

7712 Bytes) -> copied.

Load Complete - Boot in Progress

 

 

 

 

 

 

Press the Return key to display the username> prompt. Enter your name, followed by the Return key to display the Local1> prompt.

Before any configuration changes can be made, you must become the privileged user. To do this, type SET PRIV followed by the Return key.The display will then change to password> .Type SYSTEM , then press the Return key. This changes the ETHER-COM to the Local>> prompt.

Enter the following commands at the Local>> prompt:

1.CHANGE IPADDRESS xxx.xxx.xxx.xxx (where xxx... is the IP address for the unit. Note: This address must be unique to the network).

2.CHANGE GATEWAY xxx.xxx.xxx.xxx (where xxx... is the IP address for the Gateway or router attached to this LAN segment).

3.CHANGE SUBNET MASK xxx.xxx.xxx.xxx (where xxx... is the subnet mask provided by the network administrator)

4.CHANGE SPEED xxx (where xxx is the baud rate configured on the 462N (300 to 9600 baud)).

Ether-Com Programming

2841 E. Industrial Drive Springfield, MO 65802-6310 800-641-4282

2

Page 2
Image 2
DMP Electronics LT-0424 manual Change Rarp Disabled, Init, Ether-Com Programming