TROUBLESHOOTING (cont’d)

ERROR CODE CORRECTIVE PROCEDURES

Condition

Mode Switch in SERVICE position. Valve Open Limit Switch problem.

Valve Closed Limit Switch problem.

Insufficient vacuum in system.

Flush valve motor relay failure.

Corrective Action

Return Mode Switch to NORMAL position.

With the flush valve fully open, check the “VALVE OPEN” status light. If the light is off, then the Valve Open Limit Switch is out of alignment or defective, or related wiring is defective.

With flush valve in the fully closed position check the “VALVE CLOSED” status light. If the light is off, then the Valve Closed Limit Switch is out of alignment or defective, or related wiring is defective.

Check the “HI VAC” status light. If the light is off, the signal from the vac- uum switch located on the vacuum generator or vacuum tank is absent and preventing the toilet from flushing in the NORMAL mode. Check for loss of power to the vacuum generator or vacuum pump. Check for loose or defective wiring between the vacuum switch and the toilet.

Replace control module.

TOILET OPERATION

SYMPTOM 1. Toilet will not flush and water will not enter toilet bowl.

Condition

+5V status light is off (on far right of control module):

+5V status light is on:

Corrective Action

Check toilet fuse or circuit breaker at DC distribution panel.

Check for loose or defective wiring between control module and DC distribution panel.

Check for reverse polarity of input power to control module.

If all of above check OK, replace control module.

Input power must be 10 volts or higher.

Check control module for error codes.

Check “HI VAC” status light. If light is off, vacuum is low, preventing the toilet from flushing.

Check “HOLD TANK FULL” status light. If light is on, black water holding tank is full, preventing toilet from flushing.

Put Mode Switch in SERVICE position. If flush valve opens, go to next step. If the flush valve does not open, go to Symptom 2.

Put the Mode Switch in NORMAL position and push flush handle down while observing “FLUSH” status light. The “FLUSH” status light must come on when the handle is pressed and go off when the handle is released. If the “FLUSH” status light did not follow com- mands of handle, then flush switch or related wiring is defective.

SYMPTOM 2. Flush valve will not open when the Mode Switch is in the SERVICE position or when the flush handle is pushed while in the NORMAL position.

Procedure

Check the voltage output to the flush valve motor at jack 6, pins 9 and 10 on the control module as follows:

Corrective Action

Pull the control module out as far as the control cables will allow. Locate jack 6 at the bottom of the control module.

Remove the purple wire from pin 6.

With DC voltmeter test leads across pins 9 and 10, flip the Mode Switch between the NORMAL and SERVICE positions. If voltage is present for about two seconds in the SERVICE position, the flush valve motor or related wiring is defective. If voltage is not present, replace the control module.

12

Page 12
Image 12