Dometic 3400, 3300 owner manual Troubleshooting, Status Light Color Function, Error Codes

Models: 3400 3300

1 20
Download 20 pages 50.89 Kb
Page 14
Image 14

TROUBLESHOOTING

A volt/ohmmeter (VOM) and the Toilet Wiring Diagram may be required for this section.

Caution: Portions of this section will require that power be applied to the toilet. Keep hands away from the flush ball, motor drive arm and rotor shaft to prevent personal injury during testing and troubleshooting.

The control module uses a microprocessor to provide all the automatic and timing functions. The module is under the access cover. The control module has input and output status lights that can be used in troubleshooting the toilet.

The program in the microprocessor monitors the input and output signals during a normal flush cycle. If the inputs or outputs do not follow the commands of the program, then the microprocessor may go into a "standby" mode and flash an "error code.” The microprocessor is reset by placing the Mode switch in the SERVICE position temporarily, then returning the switch to the NORMAL position.

A safety circuit in the control module monitors flush ball operation. If foreign objects or low voltage prevent the flush ball from closing, this circuit prevents personal injury or damage to the flush valve motor. If this condition occurs, reset the control module by placing the Mode switch into the SERVICE position temporarily, then returning it to the NORMAL position.

Status Light

Color

Function

1

Valve Closed

Green

Flush valve Closed Limit Switch engaged.

2

Valve Open

Green

Flush valve Open Limit Switch engaged.

3

Flush

Green

Flush handle or wall switch in "Flush" position.

4

Add Water

Green

Flush handle or wall switch in "Add Water" position.

5

Water Valve

Green

Electric water valve energized.

6

Status

Green

Status/error codes

7

+5V

Green

Input power

ERROR CODES

 

 

 

Status Light

No. of Flashes

Pause

Condition

6

1

.5 sec.

Mode Switch in SERVICE position

6

1

2 sec.

VALVE OPEN Limit Switch problem

6

2

2 sec.

VALVE CLOSED Limit Switch problem

CONTROL MODULE STATUS LIGHTS

CLOSED

LED 1

 

VALVE

 

 

OPEN

LED 2

 

VALVE

 

 

FLUSH LED 3

WATER

LED 4

 

ADD

 

 

VALVE

LED 5

 

WATER

 

 

STATUS LED 6

+5V LED 7

14

Page 14
Image 14
Dometic 3400, 3300 Troubleshooting, Status Light Color Function, Error Codes, Status Light No. of Flashes Pause Condition