![](/images/new-backgrounds/1046940/4694027x1.webp)
TROUBLESHOOTING
A volt/ohmmeter (VOM) and the Toilet Wiring Diagram may be required for this section.
Caution: Portions of this section will require that power be applied to the toilet. Keep hands away from the flush ball, motor drive arm and rotor shaft to prevent personal injury during testing and troubleshooting.
The control module uses a microprocessor to provide all the automatic and timing functions. The module is under the access cover. The control module has input and output status lights that can be used in troubleshooting the toilet.
The program in the microprocessor monitors the input and output signals during a normal flush cycle. If the inputs or outputs do not follow the commands of the program, then the microprocessor may go into a "standby" mode and flash an "error code.” The microprocessor is reset by placing the Mode switch in the SERVICE position temporarily, then returning the switch to the NORMAL position.
A safety circuit in the control module monitors flush ball operation. If foreign objects or low voltage prevent the flush ball from closing, this circuit prevents personal injury or damage to the flush valve motor. If this condition occurs, reset the control module by placing the Mode switch into the SERVICE position temporarily, then returning it to the NORMAL position.
Status Light | Color | Function | |
1 | Valve Closed | Green | Flush valve Closed Limit Switch engaged. |
2 | Valve Open | Green | Flush valve Open Limit Switch engaged. |
3 | Flush | Green | Flush handle or wall switch in "Flush" position. |
4 | Add Water | Green | Flush handle or wall switch in "Add Water" position. |
5 | Water Valve | Green | Electric water valve energized. |
6 | Status | Green | Status/error codes |
7 | +5V | Green | Input power |
ERROR CODES |
|
|
|
Status Light | No. of Flashes | Pause | Condition |
6 | 1 | .5 sec. | Mode Switch in SERVICE position |
6 | 1 | 2 sec. | VALVE OPEN Limit Switch problem |
6 | 2 | 2 sec. | VALVE CLOSED Limit Switch problem |
CONTROL MODULE STATUS LIGHTS
CLOSED | LED 1 |
| |
VALVE |
|
|
OPEN | LED 2 |
| |
VALVE |
|
|
FLUSH LED 3
WATER | LED 4 |
| |
ADD |
|
|
VALVE | LED 5 |
| |
WATER |
|
|
STATUS LED 6
+5V LED 7
14