■Ventilation

11

Ventilation

If you are considering integrating a Dometic refreshment center into the furniture, don’t forget that the cooling unit needs fresh air! These sketches show various ways to integrate and ventilate a unit.The

Min. 31 in2 (200 in2) Manual background

open cross-section for fresh air supply and extracted air must be at least 31 square inches (200 cm2 ), and the air flow around the cooling unit should be unrestricted. If you have any questions, Dometic’s experts will be happy to answer them.

Sufficient ventilation can be accomplished even in taller furniture. For proper cooling, the air needs to flow freely around the cooling unit and exit freely at the top.

The opening for supply air can also be built into the furniture base, but the footprint must not prevent the air from passing the cooling unit freely.

Should you want to place the unit on the floor panel of your furniture, be sure to use the optional 1-5/8” (42 mm) feet.These and an air grille integrated in the furniture door ensure sufficient ventilation. Both doors can be connected with a slide hinge which compensates for the different pivot points.