SPECIFICATIONS
3
Model | Nominal |
No. | Capacity |
| (BTU/HR) |
| Cooling |
630025.331 | 13,500 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Electrical
Rating
120VAC,
60 Hz., 1 PH
Compressor | Compressor | Fan Motor | Fan Motor | Total | Refrigerant | |
Rated Load | Locked | Rated Load | Locked | Speed | Static | |
Amps | Rotor | Amps | Rotor | Max/Min | Max/Min |
|
| Amps |
| Amps |
| W.C. |
|
12.4 | 60.0 | 3.5 | 10.0 | 335 / 250 | .012 / 0.65 | 23.5 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Minimum Wire Size*
12AWG
Copper
Up To 24'
AC Circuit | Installed | Minimum |
Protection | Weight | Generator |
***User | (Pounds) | Size** |
Supplied |
| 1Unit/2Units |
20 Amp | 99 | 3.5 KW / 5.0 KW |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
*For wire length over 24 ft., consult the National Electric Code for proper sizing.
**Dometic Corporation gives GENERAL guidelines for generator requirements. These guidelines come from experiences people have had in actual applications. When sizing the generator, the total power usage of your recreational vehicle must be considered. Keep in mind generators lose power at high altitudes and from lack of maintenance.
***CIRCUIT PROTECTION: Time Delay Fuse or HACR Circuit Breakers Required.