AIR CONDITIONING CHOICES
There are two basic types of auxiliary air systems:
•
•Split systems
The
Dometic’s patented split systems consist of two separate modules. The outside unit contains the condenser and cooling fan. It can be bolted horizontally to the underside or vertically to the back of the sleeper. The inside unit contains the compressor, evaporator, blower,
covered by a
Each approach offers advantages and disadvantages. A
Split system inside unit under bunk. | holes in the floor for air to flow to and from the condenser. A |
| |
| split system, on the other hand, has more installation flexibility |
| |
| and uses less interior space. It also is quieter, since the con- |
| denser fan is located outside the truck. |
| Both types of air conditioning systems are available with a |
| selection of |
| through the same ducts and grills and controlled by the same |
| thermostat. They can also be used in conjunction with a diesel- |
| fired heater if desired, under control of the same thermostat. |
|
|
Split system external condenser.
|
|
|
|
|
|
|
|
|
|
| *Under normal conditions. |
| |||
|
| Heating Capacity |
| Application* |
|
|
|
| |||||||
|
|
|
|
|
|
|
|
|
|
| Whichever type of system you |
| |||
|
| 1.0 KW |
|
| 48 in. sleeper |
|
|
|
| ||||||
|
|
|
|
|
|
|
|
|
|
| select, it will come with ducts, |
| |||
|
| 2.0 KW |
|
| 60 in. sleeper |
|
|
|
| ||||||
|
|
|
|
|
|
| grills, condensate drains, thermo- |
| |||||||
|
|
|
|
|
|
|
|
|
|
|
| ||||
|
| 2.5 KW |
|
| 72 in. sleeper |
|
|
|
| ||||||
|
|
|
|
|
|
| stat controls and electrical wiring. |
| |||||||
|
|
|
|
|
|
|
|
|
|
|
| ||||
|
| 4.0 KW two stage |
| 60 or 72 in. sleeper in cold climates |
|
|
|
|
|
| |||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| Split Systems |
|
|
|
|
|
|
| |
|
|
|
|
|
|
|
|
|
|
|
|
| |||
| Model | Cool Capacity | Heat Capacity | Control | Height | Width | Length | Weight | Cool | Heat | Refrigerant |
| |||
|
|
| (BTU) |
|
|
| (in.) | (in.) | (in.) |
| (lb.) | Amps | Amps |
|
|
|
|
|
|
| Internal Unit - Evaporator/Heater/Compressor |
|
|
|
|
|
| ||||
|
|
|
|
|
|
|
|
|
|
|
|
| |||
| ECEQ7 | 7,000 | Cooling only | Smart digital | 11.75 | 10.25 | 19.25 | 53 | 7.3 | n/a | R417a |
| |||
|
|
|
|
|
|
|
|
|
|
|
|
| |||
| EHCEQ7 | 7,000 | 1 KW | Smart digital | 11.75 | 10.25 | 19.25 | 53 | 7.3 | 8.2 | R417a |
| |||
|
|
|
|
|
|
|
|
|
|
|
|
| |||
| ECEQ10 | 10,000 | Cooling only | Smart digital | 11.63 | 11.12 | 20.19 | 60 | 11.8 | n/a | R417a |
| |||
|
|
|
|
|
|
|
|
|
|
|
|
| |||
| EHCEQ10 | 10,000 | 7500 BTU | Smart digital | 11.63 | 11.12 | 20.19 | 60 | 11.8 | 1.0 | R417a |
| |||
|
|
|
|
|
|
|
|
|
|
|
|
| |||
| EHCEQ10 | 10,000 | 1.5 KW | Smart digital | 11.63 | 11.12 | 20.19 | 62 | 11.8 | 13 | R417a |
| |||
|
|
|
|
|
|
|
|
|
|
|
|
| |||
| EHCEQ10 | 10,000 | 2 KW | Smart digital | 11.63 | 11.12 | 20.19 | 62 | 11.8 | 17 | R417a |
| |||
|
|
|
|
|
|
|
|
|
|
|
|
| |||
| ECEQ14 | 14,000 | Cooling only | Smart digital | 11.69 | 13 | 22 | 64 | 14.5 | n/a | R417a |
| |||
|
|
|
|
|
|
|
|
|
|
|
|
| |||
| EHCEQ14 | 14,000 | 1.5KW | Smart digital | 11.69 | 13 | 22 | 65 | 14.5 | 13 | R417a |
| |||
|
|
|
|
|
|
|
|
|
|
|
|
| |||
| EHCEQ14 | 14,000 | 2.5 KW | Smart digital | 11.69 | 13 | 22 | 65 | 14.5 | 21 | R417a |
| |||
|
|
|
|
|
|
|
|
|
|
|
|
| |||
| EHCEQ14 | 14,000 | 2.5 KW, | Smart digital | 11.69 | 13 | 22 | 65 | 14.5 | 11.4 + 10.4 | R417a |
| |||
|
|
|
|
|
|
|
|
|
|
|
|
| |||
| EHCEQ14 | 14,000 | 4 KW, | Smart digital | 11.69 | 13 | 22 | 65 | 14.5 | 23.2 + 12.1 | R417a |
| |||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| External Unit - Condenser |
|
|
|
|
|
|
| |
|
|
|
|
|
|
|
|
|
|
|
|
| |||
| ACCD7 | 7,000 | n/a | n/a | 6.125 | 11.3125 | 21.875 | 10 | n/a | n/a | R417a |
| |||
|
|
|
|
|
|
|
|
|
|
|
|
| |||
| ACCE10 | 10,000 | n/a | n/a | 6.125 | 12.5 | 24.5 | 12 | n/a | n/a | R417a |
| |||
|
|
|
|
|
|
|
|
|
|
|
|
| |||
| ACCE14 | 14,000 | n/a | n/a | 6.625 | 12.5 | 24.5 | 13 | n/a | n/a | R417a |
| |||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||
|
|
|
|
|
|
|
|
|
|
|
|
| |||
| ASCF7 | 7,000 | Cooling only | Mechanical | 12.5 | 15.25 | 21.5 | 62 | 8.5 | n/a | R22 |
| |||
|
|
|
|
|
|
|
|
|
|
|
|
| |||
| ASCEQ7 | 7,000 | Cooling only | Smart digital | 11.94 | 17.75 | 24 | 70 | 8.9 | n/a | R417a |
| |||
|
|
|
|
|
|
|
|
|
|
|
|
| |||
| ASCEQ7 | 7,000 | 7500 BTU | Smart digital | 11.94 | 17.75 | 24 | 70 | 8.9 | 1.8 | R417a |
| |||
|
|
|
| Espar ready |
|
|
|
|
|
|
|
|
|
|
|
| ASCEQ7 | 7,000 | 1 KW | Smart digital | 11.94 | 17.75 | 24 | 71 | 8.9 | 9.5 | R417a |
| |||
|
|
|
|
|
|
|
|
|
|
|
|
| |||
| ASCEQ7 | 7,000 | 1.5 KW | Smart digital | 11.94 | 17.75 | 24 | 71 | 8.9 | 13.4 | R417a |
| |||
|
|
|
|
|
|
|
|
|
|
|
|
| |||
| ASCDQ10 | 10,000 | Cooling only | Smart digital | 12.5 | 20.87 | 28.25 | 91 | 12.9 | n/a | R22 |
| |||
|
|
|
|
|
|
|
|
|
|
|
|
| |||
| ASCDQ10 | 10,000 | 1.5 KW | Smart digital | 12.5 | 20.87 | 28.25 | 92 | 12.9 | 13.9 | R22 |
| |||
|
|
|
|
|
|
|
|
|
|
|
|
| |||
| ASCDQ10 | 10,000 | 2 KW | Smart digital | 12.5 | 20.87 | 28.25 | 92 | 12.9 | 18.2 | R22 |
| |||
|
|
|
|
|
|
|
|
|
|
|
|
| |||
| ASCDQ14 | 14,000 | 2 KW | Smart digital | 12.5 | 20.87 | 31.5 | 104 | 15.7 | 19 | R22 |
| |||
|
|
|
|
|
|
|
|
|
|
|
|
| |||
| ASCDQ14 | 14,000 | 2.5 KW | Smart digital | 12.5 | 20.87 | 31.5 | 104 | 15.7 | 23 | R22 |
| |||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|