CERTIFIED INSTALLATION
Certified installations require one roof vent and one lower side vent.
For “Certified Vent System Kits” see page 15.
For further information contact your dealer or distributor.
NOTE: The upper vent should be centered over the condenser coil at the back of the refrigerator.
Minimum ventilation height
Condenser
FIG. 9
METHODS OF INSTALLATION
The method of installation is shown in FIG. 9.
It is essential that all maximum or minimum dimensions are strictly maintained, as the performance of the refrig- erator is dependent on adequate flow of air over the rear of the refrigerator.
VENTILATION HEIGHTS
Installation with roof | Minimum ventilation | |
vent and lower side vent | heights in: |
|
|
|
|
Refrigerator | Inches | mm |
|
|
|
RM2652 | 1465 | |
RM2852 | 1620 | |
|
|
|
| G |
K | K |
FIG. 10 | L |
|
NOTE: Wood Strip
MUST be in place
N
M
CLEARANCES
Minimum clearances in inches to combustible materials
are: |
|
|
G: | Top | 0 |
K: | Side | 0 |
L:Bottom 0
M:Rear 0
N:See NOTE: Clearance “N” below.
NOTE: Clearance “M” is between the rearmost part of the refrigerator and the wall behind the refrigerator.
NOTE: Clearance “N” is the distance between the bot- tom of the lower side vent to the roof material. For ven- tilation height, see table VENTILATION HEIGHTS.
See Figures 9 and 10.
7