Dometic RM2852, RM2652 Start Up Instructions, Gas Mode, Auto Mode, To Shut Off The Refrigerator

Models: RM2852 RM2652

1 20
Download 20 pages 37.83 Kb
Page 9
Image 9
START UP INSTRUCTIONS

 

 

 

Refrigerator control panel

 

A

 

B

ON

AUTO

 

CHECK

1

 

2

AUTOMATIC REFRIGERATOR TEMPERATURE CONTROL

OFF

 

GAS

 

START UP INSTRUCTIONS

GAS MODE

A.A continuous 12 volt DC supply must be available for the electronic control to function.

B.Press the main power ON/OFF button (1) to the DOWN position.

C.In AUTO mode operation, the temperature is con- trolled by a factory preset temperature setting, on the energy source selected by the control system.

D.In GAS mode operation, the temperature is controlled by a factory preset temperature setting.

AUTO MODE

1.Press the AUTO/GAS mode selector button (2) to the DOWN position. The AUTO mode indicator lamp

(A)will illuminate. If 120 volts AC is available, the control system will select AC operation. If 120 volts AC is not available, the control system will automati- cally switch to GAS operation. Within 45 seconds the burner should be ignited and operating normally.

2.If the CHECK indicator lamp (B) illuminates, the con- trol has failed to ignite the burner on GAS.

To reset when the CHECK indicator lamp (B) is illu- minated, press the main power ON/OFF button (1) to the OFF then ON position.

3.On the initial refrigerator start-up on gas (120 volts AC is not available), it may take longer than 45 sec- onds to allow air to be purged from the gas line.

If the refrigerator has not been used for a long time or the LP tanks have just been refilled, air may be trapped in the supply lines. To purge the air from the lines may require resetting the main power ON/OFF button (1) three or four times. If repeated attempts fail to start the LP gas operation, check to make sure that the LP gas supply tanks are not empty and all manual shutoff valves in the lines are open. If the problem is still not corrected, contact a service cen- ter for assistance.

NOTE: Do not continue to reset GAS operation if the CHECK indicator lamp continues to be illuminated after several tries.

4.In AUTO mode operation, the temperature is con- trolled by a factory preset temperature setting.

1.Move the AUTO/GAS mode selector button (2) to the UP position. The AUTO mode indicator lamp (A) will go off. Within 45 seconds the burner should be ignited and operating normally.

2.If the CHECK indicator lamp (B) illuminates, the con- trol has failed to ignite the burner on GAS.

To reset when the CHECK indicator lamp (B) is illu- minated, press the main power ON/OFF button (1) to the OFF then ON position.

3.On the initial refrigerator start-up on gas, it may take longer than 45 seconds to allow air to be purged from the gas line. If the refrigerator has not been used for a long time or the LP tanks have been refilled, air may be trapped in the supply lines. To purge the air from the lines may require resetting the main power ON/OFF button (1) three or four times. If repeated attempts fail to start the LP gas operation, check to make sure that the LP gas supply tanks are not empty and all manual shutoff valves in the lines are open. If the problem is still not corrected, contact a service center for assistance.

NOTE: Do not continue to reset GAS operation if the CHECK indicator lamp continues to be illuminated after several tries.

4.In GAS mode operation, the temperature is controlled by a factory preset temperature setting.

TO SHUT OFF THE REFRIGERATOR

The refrigerator may be shut off while in any mode of operation by pressing the main power ON/OFF button to the UP (OFF) position. This shuts off all DC power to the control system.

9

Page 9
Image 9
Dometic RM2852 manual Start Up Instructions, Gas Mode, Auto Mode, To Shut Off The Refrigerator, Refrigerator control panel