The SANnet II 200 SCSI array terminator board is a field-serviceable FRU that supplies the SCSI termination throughout a base enclosure. It is hot-serviceable but not hot-swappable, so replacing one will require planned downtime. The termination module is essentially hidden between controllers, so it requires the removal of controllers before it can be replaced.

To remove a termination module, first remove all controllers and then remove the termination module by pulling it out from the enclosure. In configurations with single controllers, you must remove the blank controller panel as well as the controller. To install a termination module, slide it into the enclosure until it stops. Reinstall the controllers when done. There is no termination module within expansion enclosures.

FIGURE 10: Termination Module