Dot Hill Systems 200 manual RAID Expansion, Redundant Controllers

Models: 200

1 35
Download 35 pages 11 Kb
Page 26
Image 26

 

Head: 64,127,255 or variable

 

Cylinder: <1024, <32784,<65536 or variable

 

 

Drive motor spin-up

Supported

 

The controller will send spin-up (start unit) command to each

 

drive at 4 sec. intervals.

 

 

Drive-side tag command queue

Supported

 

User adjustable up to 128 for each drive

 

 

Host-side maximum queued I/O count

Supported

 

User adjustable up to 1024

 

 

Maximum concurrent host LUN connection

Supported

 

User adjustable up to 64

 

 

Number of tags reserved for each host LUN

Supported

connection

User adjustable up to 256

 

 

Drive I/O timeout

Supported

 

User adjustable

 

 

RAID Expansion

 

 

 

On-line RAID expansion

Supported

 

 

Mode-1 RAID expansion-add drive

Supported

 

Multiple drives can be added concurrently.

 

 

Mode-2 RAID expansion – copy and

Supported

replace drives

Replace members with drives of larger capacity.

 

 

Expand capacity with no extra drive bays

Supported in Mode 2 RAID expansion. Provide “Copy and

required

Replace Drive” function to replace drives with drives of greater

 

capacity. No need to add another enclosure for the extra drives.

 

 

Operating environment support for RAID

No operating environment driver required. No software has to be

expansion

installed for this purpose.

 

 

Redundant Controllers

 

 

 

Active-active redundant controller

Supported

 

 

Synchronized cache for both controllers

Supported

 

Through a dedicated synchronizing channel, synchronized cache

 

over Fibre loops is supported.

 

 

Write-back cache enabled in redundant

Supported

controller mode

Using synchronized cache connection between controllers.

 

 

Automatic failover

Supported

 

 

Automatic failback

Supported

 

 

Controller hot-swap

Supported

 

Support on-line hot-swap of the failed controller. There is no need

 

to reset or shutdown the failed controller. One redundant

 

controller can be pulled out during use.

 

 

Redundant controller communication

RAID: SCSI; RCC Reset signals built-in

channel

 

 

 

26

Page 26
Image 26
Dot Hill Systems 200 manual RAID Expansion, Redundant Controllers