Drolet 1800 EPA owner manual Chimney Connector, C Brick Thimble

Models: 1800 EPA

1 40
Download 40 pages 18.65 Kb
Page 22
Image 22

FIGURE 2.2.2 (C) Brick Thimble

2.3CHIMNEY CONNECTOR

Your chimney connector (commonly called stove pipe) and chimney must have the same diameter as the stove’s exhaust outlet. The stove pipe must be made of aluminized or cold roll steel with a minimum 24-gauge thickness (0.021" or 0.53 mm). It is strictly forbidden to use galvanized steel.

The following recommendations may be useful for the installation of your chimney connector:

Your chimney connector should be assembled in such a way that the male end (crimped) faces down to prevent creosote dripping outside the joints. Attach each of the sections to one another with three equidistant metal screws. Also use three equidistant metal screws to attach the connector to the stove’s exhaust collar. See Figure 2.3 (A) and Figure 2.3 (B).

The pipe must be short and straight. All sections installed horizontally must slope at least ¼ inch per foot, with the upper end of the section toward the chimney. See Figure 2.3 (B).

To insure a good draft, the total horizontal length of the connector should never exceed 8' to 10' (2.4 to 3.04 m). In the case of vertical installation, the total length of the connector can be much longer and connected without problem to the chimney at the ceiling level.

There should never be more than two 90 degrees elbows in the whole connector and chimney system. Never start with a 90o elbow. Always go up vertically for at least 2 feet from the flue spigot before using a 90o elbow.

The connector must not pass through any combustible material, nor may it pass through a concealed space (such as an attic, roof space, or closet). If passing through a wall, ceiling, or into a masonry chimney, use either chimney components listed for that specific use, or means acceptable to local authorities having jurisdiction over the installation.

Il n'est pas recommandé d'installer une clef de tuyau. En effet, sur un poêle à bois à combustion contrôlée, le tirage est réglé à l'entrée de l’air de combustion dans le poêle, et non à la sortie des gaz.

Furthermore, installation of a draft damper is not recommended. Indeed, with a controlled combustion wood stove, the draft is regulated upon intake of the combustion air in the stove and not at the exhaust.

21

Page 22
Image 22
Drolet 1800 EPA owner manual Chimney Connector, C Brick Thimble

1800 EPA specifications

The Drolet 1800 EPA wood stove is designed for efficiency and comfort, providing a robust heating solution that meets modern environmental standards. Engineered to burn wood efficiently, this appliance exemplifies the perfect blend of traditional craftsmanship and contemporary technology, making it a popular choice for homeowners seeking to maximize heat output while minimizing environmental impact.

One of the standout features of the Drolet 1800 EPA is its high-efficiency rating. With an impressive efficiency of up to 78%, this stove ensures that more of the firewood used is converted into usable heat. This not only reduces the frequency of loading wood but also lowers heating costs, making it an economical choice for homeowners. The stove is capable of heating spaces up to 1,800 square feet, making it suitable for various room sizes, from cozy living rooms to expansive open areas.

The design of the Drolet 1800 EPA includes a large, front-loading door with a glass window that allows for a captivating view of the flames. This aesthetic feature enhances the ambiance of any space, contributing to a warm and inviting atmosphere. The stove's firebox is constructed from durable steel and lined with refractory bricks, ensuring optimal combustion and heat retention.

In terms of technology, the Drolet 1800 EPA is equipped with a secondary combustion system that promotes complete combustion of gases and particulates. This process not only increases efficiency but also reduces emissions, enabling the stove to comply with strict EPA standards. The air control system allows users to easily adjust the combustion airflow, providing greater control over the burn rate and heat output.

The stove's compact size does not compromise its performance; it features a 6-inch chimney connector that allows for straightforward installation and compatibility with various venting configurations. Additionally, the Drolet 1800 EPA is designed with safety in mind, incorporating features like a protective heat shield and a secure ash drawer for easy cleaning and maintenance.

Overall, the Drolet 1800 EPA wood stove combines modern technology, classic design, and environmental responsibility, making it an ideal choice for anyone looking to enhance their home heating solution. Whether you're using it as a primary heating source or as a supplemental unit, the Drolet 1800 EPA promises efficiency, style, and comfort for years to come.