ECO-45 FREESTANDING PELLET STOVE

Width: 27”
Height: 30 1/2”
Depth: 24 5”
Weight: 230 lbs.
Flue size: 3” or 4”
Hopper Capacity: Up to 60 lbs.
(This can vary widely depending on pellet size, length, and diameter)
EPA status: exempt
Burn rate: 1.3 lbs to 5.5 lbs per hour
BTU range: 8,200 to 45,000
Electrical consumption: 3.5 Amps lighting cycle
2.5 Amps. continuous duty
Control board fuses: Main: 7.5A-250V fastblow
Igniter: 5A-250V fastblow
Electrical requirement: 120VAC 15A
Approved installations: mobile home, conventional

PREPARATION

Factory packaging must be removed, and some minor assembly work is
required prior to installation:
The black knob must be attached to heat exchanger rod;
The black coil handle must be attached to the handle rod.

CLEARANCES

The ECO-45 has been tested and listed for installation in residential, mobile
home.(refer figure 1 & 2)
FLOOR PROTECTION: minimum 6” in the front and 6” on each side. The
stove must be placed on a continuous (grouted joints) noncombustible material
such as ceramic tile, cement board, brick, 3/8” millboard or equivalent, or other
approved or listed material suited for floor protection. NOTE: ceramic tile, or
any tile, requires a continuous sheet beneath to prevent the possibility of
embers falling through to the combustible floor if cracks or separation should
occur in the finished surface, this would include floor protection for Built-in
raised hearths. Check local codes for approved alternatives.
Clearances are measured from the sides, back and face (door opening) or
stove body (refer to fig. 3).
DO NOT USE MAKESHIFT MATERIALS OR COMPROMISES IN THE
INSTALLATION OF THIS UNIT.
INSTALL VENT WITH CLEARANCES SPECIFIED BY THE VENT
MANUFACTURER.
3"
SIDE WALL
6"
2" *
BACK WALL
ADJACENT WALL
2"
ADJACENT WALL
2"
3"
3"

6"

6" 6"

IN
S
TALLATI
O
N
5

FIGURE 1

Back wall installation

FIGURE 2

Corner installation

FIGURE 3

Floor protection