A. VERTICALLY WITH NEW CHIMNEY SYSTEM (Refer to
Figure 9 & 10 for basement installation)
NOTE: Follow the vent manufacturer’s instructions.
OPTION: To achieve a center vertical installation, a 45º elbow and
a clean-out tee can be used to offset the pipe from the exhaust
outlet to the rear center of the stove.
OPTION: Install an elbow in place of clean-out tee. Locate stove.
Drop plumb bob to center of tee outlet, mark point on ceiling. Install
ceiling support and vent as per vent manufacturer’s instructions.
1. Always maintain 3” clearance from combustible materials.
When passing through additional floors or ceilings, always
install firestop spacer.
2. After lining up for hole in roof, cut either around or square hole
in roof, always 3” larger all the way around pipe. Install upper
edge and sides of flashing under roofing materials, nail to the
roof along upper edge. Do not nail lower edge. Seal nail heads
with non-hardening waterproof mastic.
3. Apply non-hardening, waterproof mastic where the storm collar
will meet the vent. Slide storm collar down until it sits on the
flashing. Seal and install cap. Mobile home installations must
use a spark arrester.
B. VERTICALLY INTO EXISTING CHIMNEY SYSTEM
As an alternative, 3” or 4” vent can be run inside existing chimney to
termination(Figure 11). This is the preferred method.
Follow guidelines for equivalent vent length.
CLEAN OUT
TEE
CLEAN OUT
TEE
FOLLOW CHIMNEY OR
VENT MANUFACTURER'S
INSTRUCTIONS

BASEMENT INSTALLATION

FOR BASEMENT INSTALLATION
A 4" PIPE IS RECOMMANDED
WALL
STRAP

FIGURE 9

Venting through roof

IN
S
TALLATI
O
N
8

FIGURE 11

Venting through existin chimne

FIGURE 10

Basement installation