1.0 INTRODUCTION

1.1 Specifications

TABLE 1

ITEM

NATURAL GAS (NG)

PROPANE (LPG)

INPUT: Hi

32,500 Btu/hr

(9.5 kW)

27,000 Btu/hr

(7.9 kW)

INPUT: Lo

22,500 Btu/hr

(6.6 kW)

21,000 Btu/hr

(6.2 kW)

MANIFOLD PRESSURE: Hi

3.5” w.c. (0.82kPa)

10.0” w.c. (2.49kPa)

MANIFOLD PRESSURE: Lo

1.7” w.c. (0.42kPa)

6.3” w.c. (1.37kPa)

GAS INLET SUPPLY

Minimum: 5.0” w.c. (1.25 kPa)

Minimum: 11” w.c. (2.74 kPa)

PRESSURE:

Maximum: 10.5” w.c. (1.74 kPa)

Maximum: 13” w.c. (3.24 kPa)

ORIFICE SIZE: @ 0-4500’

2 x #57 DMS (2 x 0.043”)

7/64“ (0.109”)

AIR SHUTTER OPENING

*Completely open

Completely open*

CONTROL VALVE TYPE:

Honeywell or SIT 820 Nova

Honeywell or SIT 820

VENTING

Simpson Dura-Vent and

Simpson Dura-Vent and

 

Security Secure Vent

Security Secure Vent

Combustion efficiency (fan off)

70.7%

68.7%

on maximum

 

 

 

 

Combustion efficiency (fan on)

73.3%

72.3%

on maximum

 

 

 

 

FAN

Variable Speed (120v / 60hz)

Variable Speed (120v / 60hz)

*May vary (±25%) depending on the installations. Judgment of installer is required.

REGISTER YOU WARRANTY ONLINE

To receive full warranty coverage, you will need to show evidence of the date you purchased your stove. Keep your sales invoice. We also recommend that you register your warranty online at www.drolet.ca

Registering your warranty online will help us track rapidly the information we need on your stove.

This heating unit must serve as a supplementary heat source. An alternative heat source should be available in the home if needed. The manufacturer cannot be responsible for additional heating costs associated with the use of an alternative heat source.

It is highly recommended that the user buys this product from a retailer who can provide installation and maintenance advices.