5.0 TROUBLE SHOOTING

5.0 TROUBLE SHOOTING

SYMPTOM

POSSIBLE CAUSE

CORRECTIVE ACTION

 

 

 

I.Pilot will not light after A. No spark at electrode (weak or not heat source for pilot ignition) repeated triggering of the

piezo ignition button

 

1.

Improper ignition

1.

Align the electrode with 1/8” (3mm) gap

 

 

 

 

 

to pilot hood

 

 

2.

Poor connections at igniter

2.

Reconnect if loose

 

 

 

and ignition electrode

 

 

 

 

3.

Broken ceramic cover on

3.

Replace pilot assembly

 

 

 

ignition electrode

 

 

 

 

4.

Defective piezo igniter

4.

Replace piezo igniter

 

 

B. No gas or low gas pressure

 

 

 

 

1.

Gas line shut off(s) may not be

1.

Turn of shut-off valves

 

 

 

turned on

 

 

 

 

2.

No gas supply (LPG)

2.

Check propane tank; you may be out of

 

 

 

 

 

fuel

 

 

3.

Air in gas lines

3.

Purge gas lines

 

 

4.

Gas lines may not be

4.

Connect all gas lines

 

 

 

connected

 

 

 

 

5.

Low pressure may be caused

5.

Check for a kinked line

 

 

 

by bent line

 

 

 

 

6.

Valve control knob not fully

6.

Fully depress control knob

 

 

 

depressed in “PILOT” position

 

 

 

II. Pilot will not stay lit after

A. Thermocouple / Valve

 

 

 

following the lighting

 

 

 

 

 

instructions

 

 

 

 

 

 

1.

Weak or improperly located

1.

Adjust and clean pilot. The flame must

 

 

 

pilot flame

 

impinge on or engulf the thermocouple.

 

 

2.

Defective thermocouple

2.

Have the thermostat contacts open and

 

 

 

 

 

pilot lit with the knob turned to the "Pilot"

 

 

 

 

 

position. Reading should be a minimum

 

 

 

 

 

of 18 mV for a new thermocouple, if the

 

 

 

 

 

reading is less than 18mV replace the

 

 

 

 

 

thermocouple.

 

 

3.

Thermocouple not installed

3.

Make sure all wire connections at the gas

 

 

 

properly

 

valve terminals are tight and the

 

 

 

 

 

thermocouple is fully inserted into the

 

 

 

 

 

mounting bracket

 

 

4. Open wire connection in pilot

4.

Check wire continuity and connections in

 

 

 

circuit

 

the pilot circuit

 