CLEARANCES FROM COMBUSTIBLES

It is of outmost importance that the clearances to combustible materials be scrupulously respected upon installation of the stove you have selected. Refer to the tables below :

 

 

 

Single pipe / Double pipe

 

Model

A

B

C

D

E

F

AZIMUTH

7/6

23/24

16/17

13.7/12.7

34.9/35.9

27.9/28.9

AUSTRAL

7/6

23/24

16/17

13.7/12.7

34.9/35.9

27.9/28.9

BALTIC

6/6

12/12

8.5/8.5

12.7/12.7

23.9/23.9

20.4/20.4

LEGEND

6/6

12/12

8.5/8.5

12.7/12.7

23.9/23.9

20.4/20.4

MYRIAD

7/6

23/24

16/17

13.7/12.7

34.9/35.9

27.9/28.9

Floor to ceiling height must be at least 7' (84") in all cases.

The clearance between the flue pipe and a wall are valid only for vertical walls and for vertical flue pipe.

The flue pipe must not go through roof trussing, an attic, a wardrobe, a floor, a combustible partition, or similar spaces.

A flue pipe crossing a combustible wall must have a minimum clearance of 18".

To reduce flue pipe clearances from combustible materials, contact your local safety department.