ELATION Fireplace Insert 5
SPECIFICATIONS
Dimensions:
height: 20” (508 mm)
width: front: 28” (711 mm) rear: 16” (406 mm)
depth: 14 3/4” (375 mm)
Surround dimensions: Small Large
width: 40” (1016 mm) 44” (1118 mm)
height: 25 ½” (648 mm) 27 ½” (699 mm)
Glass: 5mm 28" (711 mm) x 11 ¼” (286 mm) 1400° F clear ceramic
Fuel: Natural Gas Propane
Maximum input : 25,000 (7.3) 25,000 (7.3) Btu/h (kWh)
Minimum input: 17,000 (5.0) 19,000 (5.6) Btu/h (kWh)
Manifold pressure : 3.5/1.8 (0.9/0.5) 10.5/7.0 (2.6/1.8) in w.c. (kPa)
Min. inlet pressure : 5 (1.3) 11 (2.8) in w.c. (kPa)
Max. inlet pressure : 8 (1.8) 14 (3.5) in w.c. (kPa)
Orifice size/Altitude: 42 dms 0-4500 ft 53 dms 0-4500 ft
Output capacity (Blower off): 18,500 (5.4) 18,500 (5.4) Btu/h (kWh)
Output capacity (Blower on): 20,000 (5.9) 20,000 (5.9) Btu/h (kWh)
Efficiency (Blower off): 73.5% 73.5%
Efficiency (Blower on): 80.6% 80.6%
Vent: 4” "B-vent", "L-vent" or certified flex liner
Valve: SIT model Nova 820 adjustable millivolt valve
Blower : variable speed, 130 CFM (3.68 m3/min)
Thermo-switch: 110° F (43° C) “ON”, 90° F (32° C) “OFF” bi-metal type.